Feasibility and efficacy of active breathing coordinator assisted deep inspiration breath hold technique for treatment of locally advanced breast cancer. Issue 2 (31st December 2022)
- Record Type:
- Journal Article
- Title:
- Feasibility and efficacy of active breathing coordinator assisted deep inspiration breath hold technique for treatment of locally advanced breast cancer. Issue 2 (31st December 2022)
- Main Title:
- Feasibility and efficacy of active breathing coordinator assisted deep inspiration breath hold technique for treatment of locally advanced breast cancer
- Authors:
- All, Sean
Zhao, Bo
Montalvo, Steven
Maxwell, Christian
Johns, Christopher
Gu, Xuejun
Rahimi, Asal
Alluri, Prasanna
Parsons, David
Chiu, Tsuicheng
Schroeder, Samuel
Kim, D. Nathan - Abstract:
- Abstract: Background: Active breathing coordinator (ABC)‐assisted deep inspiration breath hold (DIBH) is an important organ sparing radiation therapy (RT) technique for left‐sided breast cancer patients. Patients with advanced breast cancer undergoing chest wall and regional nodal irradiation often require a field matching technique. While field matching has been demonstrated to be safe and effective in free breathing patients, its safety and accuracy in DIBH/ABC use has not been previously reported. Purpose: To report the accuracy, feasibility, and safety of field matching with ABC/DIBH for patients receiving breast/chest wall irradiation with nodal irradiation using a three‐field technique. Methods: From December 2012 to May 2018, breast cancer patients undergoing ABC/DIBH‐based RT at a single institution were reviewed. For each fraction, the amount of overlap/gap between the supraclavicular and the tangential field were measured and recorded. Patient characteristics, including acute and delayed skin toxicities, were analyzed. Results: A total of 202 patients utilized ABC/DIBH and 4973 fractions had gap/overlap measurements available for analysis. The average gap/overlap measured at junction was 0.28 mm ± 0.99 mm. A total of 72% of fractions had no measurable gap/overlap (0 mm), while 5.6% had an overlap and 22.7% a gap. There was no significant trend for worsening or improvement of gap/overlap measurements with increasing fraction number per patient. OSLD measurementsAbstract: Background: Active breathing coordinator (ABC)‐assisted deep inspiration breath hold (DIBH) is an important organ sparing radiation therapy (RT) technique for left‐sided breast cancer patients. Patients with advanced breast cancer undergoing chest wall and regional nodal irradiation often require a field matching technique. While field matching has been demonstrated to be safe and effective in free breathing patients, its safety and accuracy in DIBH/ABC use has not been previously reported. Purpose: To report the accuracy, feasibility, and safety of field matching with ABC/DIBH for patients receiving breast/chest wall irradiation with nodal irradiation using a three‐field technique. Methods: From December 2012 to May 2018, breast cancer patients undergoing ABC/DIBH‐based RT at a single institution were reviewed. For each fraction, the amount of overlap/gap between the supraclavicular and the tangential field were measured and recorded. Patient characteristics, including acute and delayed skin toxicities, were analyzed. Results: A total of 202 patients utilized ABC/DIBH and 4973 fractions had gap/overlap measurements available for analysis. The average gap/overlap measured at junction was 0.28 mm ± 0.99 mm. A total of 72% of fractions had no measurable gap/overlap (0 mm), while 5.6% had an overlap and 22.7% a gap. There was no significant trend for worsening or improvement of gap/overlap measurements with increasing fraction number per patient. OSLD measurements were compared to the planned dose. The median dose 1 cm above the junction was 106% ± 7% of planned dose (range 94%–116%). One centimeter below the junction, the median dose was 114% ± 11% of planned dose (range 95%–131%). At the junction, the median dose was 106% ± 16.3% of planned dose (range 86%–131%). Acute skin toxicity was similar to historically reported values (grade 3, 5.4%, grade 4, 0%). Conclusion: ABC‐assisted DIBH is a safe and technically feasible method of delivering RT in the setting of complex matching field technique for breast and regional nodal treatments. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 24:Issue 2(2023)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 24:Issue 2(2023)
- Issue Display:
- Volume 24, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 24
- Issue:
- 2
- Issue Sort Value:
- 2023-0024-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-12-31
- Subjects:
- ABC, DIBH, Locally Advanced Breast Cancer, 3‐field technique, field matching
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13893 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25976.xml