Different Undercut Depths Influence on Fatigue Behavior and Retentive Force of Removable Partial Denture Clasp Materials: A Systematic Review. Issue 2 (28th April 2022)
- Record Type:
- Journal Article
- Title:
- Different Undercut Depths Influence on Fatigue Behavior and Retentive Force of Removable Partial Denture Clasp Materials: A Systematic Review. Issue 2 (28th April 2022)
- Main Title:
- Different Undercut Depths Influence on Fatigue Behavior and Retentive Force of Removable Partial Denture Clasp Materials: A Systematic Review
- Authors:
- Zheng, Jenny
Aarts, John M.
Ma, Sunyoung
Waddell, John Neil
Choi, Joanne Jung Eun - Abstract:
- Abstract: Purpose: To perform a systematic review that provides an overview of the current literature on fatigue behavior of removable partial denture (RPD) clasp materials based on different retentive areas. Materials and methods: The review followed the Preferred Reporting Items for Systematic Review and Meta‐Analyses (PRISMA) guidelines. Electronic searches were done via PubMed, Scopus, and OVID for studies reporting on RPD clasps and the fatigue failure of clasp materials. Inclusion criteria were English language with full text and in vitro studies only. Exclusion criteria were studies that did not assess the fatigue of RPD clasp materials. A quality assessment and selection of full‐text articles were performed according to Consolidated Standards of Reporting Trials criteria. Results: A total of 182 articles were initially identified and screened. After applying inclusion and exclusion criteria, 15 articles were selected for the final analysis. Seven of the included studies utilized a vertical insertion/removal testing approach. Ten studies used the constant deflection test. Three studies used untapered specimens, and 12 studies used tapered specimens. Ten studies performed post‐test analysis. Conclusions: Cobalt‐chromium (CoCr) is the strongest material in terms of fatigue in relation to the undercut depth and the modern, digitally manufactured RPD clasp materials also exhibit comparable fatigue behavior. Recent RPD clasp materials such as polyetheretherketone (PEEK) orAbstract: Purpose: To perform a systematic review that provides an overview of the current literature on fatigue behavior of removable partial denture (RPD) clasp materials based on different retentive areas. Materials and methods: The review followed the Preferred Reporting Items for Systematic Review and Meta‐Analyses (PRISMA) guidelines. Electronic searches were done via PubMed, Scopus, and OVID for studies reporting on RPD clasps and the fatigue failure of clasp materials. Inclusion criteria were English language with full text and in vitro studies only. Exclusion criteria were studies that did not assess the fatigue of RPD clasp materials. A quality assessment and selection of full‐text articles were performed according to Consolidated Standards of Reporting Trials criteria. Results: A total of 182 articles were initially identified and screened. After applying inclusion and exclusion criteria, 15 articles were selected for the final analysis. Seven of the included studies utilized a vertical insertion/removal testing approach. Ten studies used the constant deflection test. Three studies used untapered specimens, and 12 studies used tapered specimens. Ten studies performed post‐test analysis. Conclusions: Cobalt‐chromium (CoCr) is the strongest material in terms of fatigue in relation to the undercut depth and the modern, digitally manufactured RPD clasp materials also exhibit comparable fatigue behavior. Recent RPD clasp materials such as polyetheretherketone (PEEK) or laser sintered CoCr, however, require further study in terms of their fatigue behavior. In order to improve the quality of future studies, a standardized and calibrated fatigue testing method is needed with standardized specimen size and shape, which will reduce the risk of bias and enable meta‐analysis for bulk comparison between studies. … (more)
- Is Part Of:
- Journal of prosthodontics. Volume 32:Issue 2(2023)
- Journal:
- Journal of prosthodontics
- Issue:
- Volume 32:Issue 2(2023)
- Issue Display:
- Volume 32, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2023-0032-0002-0000
- Page Start:
- 108
- Page End:
- 115
- Publication Date:
- 2022-04-28
- Subjects:
- Removable partial denture -- dental clasps -- fatigue failure -- cyclic fatigue -- undercut
Prosthodontics -- Periodicals
Dental implants -- Periodicals
Dentistry -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1532-849X ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jopr ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jopr.13519 ↗
- Languages:
- English
- ISSNs:
- 1059-941X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.920000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25970.xml