Impact of implantation technique on conduction disturbances for TAVR with the self‐expanding portico/navitor valve. Issue 2 (21st December 2022)
- Record Type:
- Journal Article
- Title:
- Impact of implantation technique on conduction disturbances for TAVR with the self‐expanding portico/navitor valve. Issue 2 (21st December 2022)
- Main Title:
- Impact of implantation technique on conduction disturbances for TAVR with the self‐expanding portico/navitor valve
- Authors:
- Wang, Xi
Wong, Ivan
Bajoras, Vilhelmas
Vanhaverbeke, Maarten
Nuyens, Philippe
Bieliauskas, Gintautas
Jørgensen, Troels Højsgaard
Chen, Mao
De Backer, Ole
Sondergaard, Lars - Abstract:
- Abstract: Background: Use of a right−left (R−L) cusp overlap view for transcatheter aortic valve replacement (TAVR) with self‐expanding valves has recently been proposed aiming to reduce permanent pacemaker implantation (PPMI). An objective, data‐driven explanation for this observation is missing. Aims: To assess the impact of different implantation techniques on the risk of PPMI following TAVR with the Portico/Navitor TM transcatheter heart valve (THV; Abbott). Methods: A TAVR‐population treated with Portico/Navitor TM had the THV implanted in a right versus left anterior oblique (RAO/LAO) fluoroscopic view with no parallax in the delivery system. The impact of these different implantation views on the spatial relationship between THV and native aortic annulus and the risk of conduction disturbances and PPMI after TAVR was studied. Results: A total of 366 matched TAVR patients were studied: 183 in the RAO group and 183 in the LAO group. The degree of aortic annulus plane tilt was significantly smaller in the RAO versus LAO group (median: 0° vs. 23°, p < 0.001), with no plane tilt in 105 out of 183 cases (57.3%) in the RAO group. At 30 days after TAVR, the overall PPMI and guideline‐directed PPMI rates were 12.6% versus 18.0% ( p = 0.15) and 8.2% versus 15.3% ( p = 0.04) in the RAO versus LAO group, respectively. Conclusions: Use of a R−L cusp overlap (RAO‐caudal) view for implantation of the Portico/Navitor TM valve results in less tilt of the native aortic annulus planeAbstract: Background: Use of a right−left (R−L) cusp overlap view for transcatheter aortic valve replacement (TAVR) with self‐expanding valves has recently been proposed aiming to reduce permanent pacemaker implantation (PPMI). An objective, data‐driven explanation for this observation is missing. Aims: To assess the impact of different implantation techniques on the risk of PPMI following TAVR with the Portico/Navitor TM transcatheter heart valve (THV; Abbott). Methods: A TAVR‐population treated with Portico/Navitor TM had the THV implanted in a right versus left anterior oblique (RAO/LAO) fluoroscopic view with no parallax in the delivery system. The impact of these different implantation views on the spatial relationship between THV and native aortic annulus and the risk of conduction disturbances and PPMI after TAVR was studied. Results: A total of 366 matched TAVR patients were studied: 183 in the RAO group and 183 in the LAO group. The degree of aortic annulus plane tilt was significantly smaller in the RAO versus LAO group (median: 0° vs. 23°, p < 0.001), with no plane tilt in 105 out of 183 cases (57.3%) in the RAO group. At 30 days after TAVR, the overall PPMI and guideline‐directed PPMI rates were 12.6% versus 18.0% ( p = 0.15) and 8.2% versus 15.3% ( p = 0.04) in the RAO versus LAO group, respectively. Conclusions: Use of a R−L cusp overlap (RAO‐caudal) view for implantation of the Portico/Navitor TM valve results in less tilt of the native aortic annulus plane and a clear trend toward a lower 30‐day PPMI rate as compared to TAVR using the conventional LAO implantation view. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 101:Issue 2(2023)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 101:Issue 2(2023)
- Issue Display:
- Volume 101, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 101
- Issue:
- 2
- Issue Sort Value:
- 2023-0101-0002-0000
- Page Start:
- 431
- Page End:
- 441
- Publication Date:
- 2022-12-21
- Subjects:
- conduction disturbance -- fluoroscopic view -- implantation technique -- pacemaker implantation -- transcatheter aortic valve replacement
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.30517 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25983.xml