Impact of computed tomography metal artifact reduction protocol on periprosthetic tissue characterization after total hip arthroplasty: A cadaveric study. Issue 3 (19th June 2022)
- Record Type:
- Journal Article
- Title:
- Impact of computed tomography metal artifact reduction protocol on periprosthetic tissue characterization after total hip arthroplasty: A cadaveric study. Issue 3 (19th June 2022)
- Main Title:
- Impact of computed tomography metal artifact reduction protocol on periprosthetic tissue characterization after total hip arthroplasty: A cadaveric study
- Authors:
- Dwyer, Andrew
Korlaet, Mishelle
Callary, Stuart A.
Robertson, Thomas
Smitham, Peter
Solomon, Lucian B. - Abstract:
- Abstract: Metal artifact reduction (MAR) has improved computed tomography (CT) imaging of total hip arthroplasty (THA) but the assessment of osteolysis and implant to bone contact relies on the accurate depiction of bone defects, cancellous bone, and cement. This study evaluates the impact of available single and dual‐energy protocols on periprosthetic tissue characterization in a cadaveric phantom. Bilateral THA was performed on a fresh frozen cadaveric pelvis with simulated osteolytic cavities. CT acquisitions with projection‐based MAR and noise equivalence were performed using single energy 140 kVp, single energy 150 kVp with 0.6 mm tin filtration, and dual‐energy at 100/150 kVp with 0.6 mm tin filtration, from which simulated energies were extracted. Image subtraction, segmentation, region of interest histograms, and line profiles were used to characterize tissue density and separation. Tissue densities were heavily dependent on the energy profile of the protocol. Cancellous bone ranged from 182 to 45 HU and cement from 1012 to 131 HU using 140 kVp compared to dual‐energy with weighted high energy tube, respectively. Spectral separation between cancellous bone, osteolytic defect, and cement was reduced for all protocols compared with 140 kVp. Spectral overlap was most severe using dual‐energy with heavily weighted high‐energy tubes. Dual‐energy algorithms reduced trabecular contrast within the cancellous bone and cortical edge response. Although the dual‐energyAbstract: Metal artifact reduction (MAR) has improved computed tomography (CT) imaging of total hip arthroplasty (THA) but the assessment of osteolysis and implant to bone contact relies on the accurate depiction of bone defects, cancellous bone, and cement. This study evaluates the impact of available single and dual‐energy protocols on periprosthetic tissue characterization in a cadaveric phantom. Bilateral THA was performed on a fresh frozen cadaveric pelvis with simulated osteolytic cavities. CT acquisitions with projection‐based MAR and noise equivalence were performed using single energy 140 kVp, single energy 150 kVp with 0.6 mm tin filtration, and dual‐energy at 100/150 kVp with 0.6 mm tin filtration, from which simulated energies were extracted. Image subtraction, segmentation, region of interest histograms, and line profiles were used to characterize tissue density and separation. Tissue densities were heavily dependent on the energy profile of the protocol. Cancellous bone ranged from 182 to 45 HU and cement from 1012 to 131 HU using 140 kVp compared to dual‐energy with weighted high energy tube, respectively. Spectral separation between cancellous bone, osteolytic defect, and cement was reduced for all protocols compared with 140 kVp. Spectral overlap was most severe using dual‐energy with heavily weighted high‐energy tubes. Dual‐energy algorithms reduced trabecular contrast within the cancellous bone and cortical edge response. Although the dual‐energy acquisition has been proposed as an additive to projection‐based MAR techniques in THA, reduced density and contrast in clinically relevant periprosthetic tissue compared to 140 kVp single energy may limit its use in characterizing periprosthetic tissues. … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 41:Issue 3(2023)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 41:Issue 3(2023)
- Issue Display:
- Volume 41, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2023-0041-0003-0000
- Page Start:
- 657
- Page End:
- 662
- Publication Date:
- 2022-06-19
- Subjects:
- computed tomography -- dual energy -- metal artifact reduction -- osteolysis -- tissue density
Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.25391 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25990.xml