Drug eluting and bare metal stents in people with and without diabetes: collaborative network meta-analysis. (31st August 2008)
- Record Type:
- Journal Article
- Title:
- Drug eluting and bare metal stents in people with and without diabetes: collaborative network meta-analysis. (31st August 2008)
- Main Title:
- Drug eluting and bare metal stents in people with and without diabetes: collaborative network meta-analysis
- Authors:
- Stettler, Christoph
Allemann, Sabin
Wandel, Simon
Kastrati, Adnan
Morice, Marie Claude
Schömig, Albert
Pfisterer, Matthias E
Stone, Gregg W
Leon, Martin B
Lezo, José Suárez de
Goy, Jean-Jacques
Park, Seung-Jung
Sabaté, Manel
Suttorp, Maarten J
Kelbaek, Henning
Spaulding, Christian
Menichelli, Maurizio
Vermeersch, Paul
Dirksen, Maurits T
Cervinka, Pavel
Carlo, Marco De
Erglis, Andrejs
Chechi, Tania
Ortolani, Paolo
Schalij, Martin J
Diem, Peter
Meier, Bernhard
Windecker, Stephan
Jüni, Peter - Abstract:
- Abstract : Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point. Results 35 trials in 3852 people with diabetes and 10 947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibilityAbstract : Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point. Results 35 trials in 3852 people with diabetes and 10 947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibility interval 0.55 to 1.30), paclitaxel eluting stents compared with bare metal stents 0.91 (0.60 to 1.38), and sirolimus eluting stents compared with paclitaxel eluting stents 0.95 (0.63 to 1.43). In people without diabetes, hazard ratios were unaffected by the restriction. Both drug eluting stents were associated with a decrease in revascularisation rates compared with bare metal stents in people both with and without diabetes. Conclusion In trials that specified a duration of dual antiplatelet therapy of six months or more after stent implantation, drug eluting stents seemed safe and effective in people both with and without diabetes. … (more)
- Is Part Of:
- BMJ. Volume 337(2008)
- Journal:
- BMJ
- Issue:
- Volume 337(2008)
- Issue Display:
- Volume 337, Issue 2008 (2008)
- Year:
- 2008
- Volume:
- 337
- Issue:
- 2008
- Issue Sort Value:
- 2008-0337-2008-0000
- Page Start:
- Page End:
- Publication Date:
- 2008-08-31
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Periodicals
610 - Journal URLs:
- http://www.bmj.com/archive ↗
http://www.jstor.org/journals/09598138.html ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/3/ ↗
http://www.bmj.com/bmj/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bmj.a1331 ↗
- Languages:
- English
- ISSNs:
- 0007-1447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25980.xml