Development of Duplex and Multiplex Reverse Transcription Loop Mediated Isothermal Amplification (RT-LAMP) Assays for Clinical Diagnosis of SARS-COV-2 in Sri Lanka. (March 2022)
- Record Type:
- Journal Article
- Title:
- Development of Duplex and Multiplex Reverse Transcription Loop Mediated Isothermal Amplification (RT-LAMP) Assays for Clinical Diagnosis of SARS-COV-2 in Sri Lanka. (March 2022)
- Main Title:
- Development of Duplex and Multiplex Reverse Transcription Loop Mediated Isothermal Amplification (RT-LAMP) Assays for Clinical Diagnosis of SARS-COV-2 in Sri Lanka
- Authors:
- Hewadikaram, M.
Perera, K.
Dissanayake, K.
Ramanayake, M.
Isurika, S.C.
Panch, A.
Jayarathne, A.
Pushpakumara, P.
Malavige, N.
Jeewandara, C.
Bathige, S.D.N.K.
Mubarak, A.M. - Abstract:
- Abstract : Purpose: Despite the rollout of several vaccines targeting SARS-CoV-2, attainment of near-universal vaccination is a challenging task, particularly for low- and middle-income nations such as Sri Lanka. Rapid, reliable diagnostics for the detection of the virus is of vital importance for the predominantly export- and tourism-based economy of the country. Herein, we report the development of a RT-LAMP assay as an alternative to the gold-standard RT-qPCR method for diagnostic laboratories in Sri Lanka in a cost-effective and highly reliable manner. Methods & Materials: About 313 nasopharyngeal and oropharyngeal samples from the community were collected and subjected to RNA purification and subjected to simultaneous RT-qPCR and RT-LAMP experiments by using previously published primers in a thermocycler. Duplex (containing N and E gene primers) and multiplex (containing N, E and ORF1ab gene primers) RT-LAMP assay results were compared with standard RT-qPCR results using an agreement attribute statistical test. The effect of guanidine hydrochloride was also analyzed. Results: The limit of detection for the duplex assay was found to be 10 copies µL-1 at a constant temperature of 63°C, and 5 copies µL-1 for multiplex assays at 66.4°C. Both types of RT-LAMP assay were specific only for the SARS-COV-2 virus, successfully distinguishing it from multiple other human viruses. Attribute agreement analysis between duplex- and multiplex RT-LAMP vs RT-qPCR yielded 93% and 96.5%Abstract : Purpose: Despite the rollout of several vaccines targeting SARS-CoV-2, attainment of near-universal vaccination is a challenging task, particularly for low- and middle-income nations such as Sri Lanka. Rapid, reliable diagnostics for the detection of the virus is of vital importance for the predominantly export- and tourism-based economy of the country. Herein, we report the development of a RT-LAMP assay as an alternative to the gold-standard RT-qPCR method for diagnostic laboratories in Sri Lanka in a cost-effective and highly reliable manner. Methods & Materials: About 313 nasopharyngeal and oropharyngeal samples from the community were collected and subjected to RNA purification and subjected to simultaneous RT-qPCR and RT-LAMP experiments by using previously published primers in a thermocycler. Duplex (containing N and E gene primers) and multiplex (containing N, E and ORF1ab gene primers) RT-LAMP assay results were compared with standard RT-qPCR results using an agreement attribute statistical test. The effect of guanidine hydrochloride was also analyzed. Results: The limit of detection for the duplex assay was found to be 10 copies µL-1 at a constant temperature of 63°C, and 5 copies µL-1 for multiplex assays at 66.4°C. Both types of RT-LAMP assay were specific only for the SARS-COV-2 virus, successfully distinguishing it from multiple other human viruses. Attribute agreement analysis between duplex- and multiplex RT-LAMP vs RT-qPCR yielded 93% and 96.5% scores, respectively. Moreover, both RT-LAMP assays showed 100% agreement with RT-qPCR when Ct was <25 in positive samples and showed 100% (duplex) or 97.22% (multiplex) at 35≥ Ct ≥25. The discrepancy between agreements at higher Ct values was attributed to the higher sensitivity of the multiplex RT-LAMP assay. The addition of guanidine hydrochloride increased the sensitivity and decreased detection time significantly for both the duplex and multiplex assays. Conclusion: Overall, we have demonstrated a potentially rapidly deployable diagnostic test kit not only for widespread community use but particularly for high-risk locations such as ports of entry or manufacturing facilities to mitigate the effects of the SARS-CoV-2 virus in Sri Lanka. … (more)
- Is Part Of:
- International journal of infectious diseases. Volume 116(2022)Supplement
- Journal:
- International journal of infectious diseases
- Issue:
- Volume 116(2022)Supplement
- Issue Display:
- Volume 116, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 116
- Issue:
- 2022
- Issue Sort Value:
- 2022-0116-2022-0000
- Page Start:
- S39
- Page End:
- S40
- Publication Date:
- 2022-03
- Subjects:
- Communicable diseases -- Periodicals
Communicable Diseases -- Periodicals
Communicable diseases
Periodicals
Electronic journals
616.9 - Journal URLs:
- http://bibpurl.oclc.org/web/73769 ↗
http://www.journals.elsevier.com/international-journal-of-infectious-diseases/ ↗
http://www.sciencedirect.com/science/journal/12019712 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/12019712 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/12019712 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijid.2021.12.095 ↗
- Languages:
- English
- ISSNs:
- 1201-9712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.304750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25937.xml