Coronary artery dissection by an oversized balloon. (4th December 2014)
- Record Type:
- Journal Article
- Title:
- Coronary artery dissection by an oversized balloon. (4th December 2014)
- Main Title:
- Coronary artery dissection by an oversized balloon
- Authors:
- Yafi, Wael
Jacquemin, Laurent - Abstract:
- Abstract : Percutaneous coronary intervention (PCI) as a treatment of coronary artery disease can be a simple, rapid procedure with a clear benefit for the patient, but it could also become a complex procedure with fatal consequences. These complications depend on the lesion itself, material used and also on operating staff. In this case we report a coronary artery dissection of the circumflex (CX) artery caused by inflation of an oversized balloon. We discuss here the management and evolution of this complication.
- Is Part Of:
- BMJ case reports. Volume 2014
- Journal:
- BMJ case reports
- Issue:
- Volume 2014
- Issue Display:
- Volume 2014 (2014)
- Year:
- 2014
- Volume:
- 2014
- Issue Sort Value:
- 2014-2014-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-12-04
- Subjects:
- Medicine -- Case studies -- Periodicals
610.5 - Journal URLs:
- http://www.bmj.com/archive ↗
http://casereports.bmj.com/ ↗ - DOI:
- 10.1136/bcr-2014-207185 ↗
- Languages:
- English
- ISSNs:
- 1757-790X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25906.xml