IDEAL in Meshes for Prolapse, Urinary Incontinence, and Hernia Repair. (October 2013)
- Record Type:
- Journal Article
- Title:
- IDEAL in Meshes for Prolapse, Urinary Incontinence, and Hernia Repair. (October 2013)
- Main Title:
- IDEAL in Meshes for Prolapse, Urinary Incontinence, and Hernia Repair
- Authors:
- Gerullis, Holger
Klosterhalfen, Bernd
Borós, Mihaly
Lammers, Bernhard
Eimer, Christoph
Georgas, Evagelos
Otto, Thomas - Abstract:
- Purpose . Mesh surgeries are counted among the most frequently applied surgical procedures. Despite global spread of mesh applying surgeries, there is no current systematic analysis of incidence and possible prevention of adverse events after mesh implantation. Materials and Methods . Based on the recommendations of IDEAL an in vitro test system for biocompatibility of surgical meshes has been generated (Innovation). Coating strategies for biocompatibility optimization have been developed (Development). The native and modified alloplastic materials have been tested in an animal model over 2 years (Exploration and Assessment and Long-term study). Results . In 3 meshes, implanted in sheep and explanted at 4 different time points (a, 3 months; b, 6 months; c, 12 months; and d, 24 months) over 24 months, thickness of inflammatory tissue (TVT a, 35 µm; b, 32 µm; c, 33 µm; d, 28 µm; UltraPro, a, 25 µm; b, 24 µm; c, 21 µm; d, 22 µm; PVDF a, 20 µm; b, 21 µm; c, 14 µm; d, 15µm), connective tissue (TVT a, 37 µm; b, 36 µm; c, 43 µm; d, 41 µm; UltraPro a, 33 µm; b, 32 µm; c, 40 µm; d, 38 µm; PVDF a, 25 µm; b, 22 µm; c, 22 µm; d, 24 µm), and macrophage infiltration (TVT a, 36%; b, 33%; c, 23%; d, 20%; UltraPro a, 34%; b, 28%; c, 25%; d, 22%; PVDF a, 24%; b, 18%; c, 18%; d, 16%) revealed comparable ranking characteristics at every time point after explantation. The in vivo performance of these meshes in a sheep model was predictable with a previously developed in vitro test system.Purpose . Mesh surgeries are counted among the most frequently applied surgical procedures. Despite global spread of mesh applying surgeries, there is no current systematic analysis of incidence and possible prevention of adverse events after mesh implantation. Materials and Methods . Based on the recommendations of IDEAL an in vitro test system for biocompatibility of surgical meshes has been generated (Innovation). Coating strategies for biocompatibility optimization have been developed (Development). The native and modified alloplastic materials have been tested in an animal model over 2 years (Exploration and Assessment and Long-term study). Results . In 3 meshes, implanted in sheep and explanted at 4 different time points (a, 3 months; b, 6 months; c, 12 months; and d, 24 months) over 24 months, thickness of inflammatory tissue (TVT a, 35 µm; b, 32 µm; c, 33 µm; d, 28 µm; UltraPro, a, 25 µm; b, 24 µm; c, 21 µm; d, 22 µm; PVDF a, 20 µm; b, 21 µm; c, 14 µm; d, 15µm), connective tissue (TVT a, 37 µm; b, 36 µm; c, 43 µm; d, 41 µm; UltraPro a, 33 µm; b, 32 µm; c, 40 µm; d, 38 µm; PVDF a, 25 µm; b, 22 µm; c, 22 µm; d, 24 µm), and macrophage infiltration (TVT a, 36%; b, 33%; c, 23%; d, 20%; UltraPro a, 34%; b, 28%; c, 25%; d, 22%; PVDF a, 24%; b, 18%; c, 18%; d, 16%) revealed comparable ranking characteristics at every time point after explantation. The in vivo performance of these meshes in a sheep model was predictable with a previously developed in vitro test system. Coating of meshes with autologous plasma prior to implantation seems to have a positive effect on the meshes biocompatibility. Conclusion . We have applied IDEAL criteria on a new innovation for surgical meshes. The results permit the generation of a ranking of currently available meshes with potential to optimize future meshes. … (more)
- Is Part Of:
- Surgical innovation. Volume 20:Number 5(2013)
- Journal:
- Surgical innovation
- Issue:
- Volume 20:Number 5(2013)
- Issue Display:
- Volume 20, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 20
- Issue:
- 5
- Issue Sort Value:
- 2013-0020-0005-0000
- Page Start:
- 502
- Page End:
- 508
- Publication Date:
- 2013-10
- Subjects:
- mesh -- biocompatibility -- IDEAL -- plasma coating -- in vivo -- in vitro -- predictability
Surgery, Operative -- Periodicals
Endoscopic surgery -- Periodicals
Laparoscopic surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Diffusion of Innovation -- Periodicals
Chirurgie opératoire -- Périodiques
Chirurgie endoscopique -- Périodiques
Chirurgie laparoscopique -- Périodiques
617.91 - Journal URLs:
- http://journals.sagepub.com/home/sri ↗
http://sri.sagepub.com/ ↗
http://www.sagepub.com/journalsProdDesc.nav?prodId=Journal201793 ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1553350612472987 ↗
- Languages:
- English
- ISSNs:
- 1553-3506
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25900.xml