A case report of unexpected right-to-left shunt under mechanical support for post-infarction ventricular septal defect: evaluation with haemodynamic simulator. Issue 8 (31st August 2021)
- Record Type:
- Journal Article
- Title:
- A case report of unexpected right-to-left shunt under mechanical support for post-infarction ventricular septal defect: evaluation with haemodynamic simulator. Issue 8 (31st August 2021)
- Main Title:
- A case report of unexpected right-to-left shunt under mechanical support for post-infarction ventricular septal defect: evaluation with haemodynamic simulator
- Authors:
- Hiraoka, Arudo
Saku, Keita
Nishikawa, Takuya
Sunagawa, Kenji - Editors:
- Lorusso, Robert
De Biase, Chiare
Azzano, Alessia
Kurdi, Hibba
Sunjaya, Anthony Paulo - Abstract:
- Abstract: Background: Post-myocardial infarction ventricular septal defect (PIVSD) is a complication of acute myocardial infarction with high mortality. A percutaneous left ventricular assist device, Impella, is currently used in maintaining haemodynamic stability in PIVSD. Case summary: A 65-year-old man was transferred to our hospital for treatment of acute myocardial infarction of the proximal right coronary artery. Percutaneous intervention was performed but haemodynamic instability continued. At 10 days after onset, the patient was diagnosed with PIVSD by echocardiogram. To stabilize haemodynamics, we initiated venoarterial extracorporeal membrane oxygenation (ECMO). Three days after ECMO initiation, pulmonary congestion increased and an echocardiogram revealed closed aortic valve and spontaneous echo contrast at the aortic root. After an Impella 2.5 was inserted for unloading of the left ventricle, the oxygenation level and cardiac function rapidly declined. Unexpectedly, an echocardiogram showed a right-to-left shunt (to-and-fro pattern) via PIVSD. By increasing the ECMO and decreasing Impella flow, the shunt flow changed to left-to-right, and oxygenation level and cardiac function improved. Ten days after ECMO was started, elective surgical repair was successfully performed. Conclusion: ECPELLA (ECMO + Impella) can offset the adverse effects of isolated ECMO support and reduce the PIVSD shunt flow. However, the risk of right-to-left shunt has not been reported, andAbstract: Background: Post-myocardial infarction ventricular septal defect (PIVSD) is a complication of acute myocardial infarction with high mortality. A percutaneous left ventricular assist device, Impella, is currently used in maintaining haemodynamic stability in PIVSD. Case summary: A 65-year-old man was transferred to our hospital for treatment of acute myocardial infarction of the proximal right coronary artery. Percutaneous intervention was performed but haemodynamic instability continued. At 10 days after onset, the patient was diagnosed with PIVSD by echocardiogram. To stabilize haemodynamics, we initiated venoarterial extracorporeal membrane oxygenation (ECMO). Three days after ECMO initiation, pulmonary congestion increased and an echocardiogram revealed closed aortic valve and spontaneous echo contrast at the aortic root. After an Impella 2.5 was inserted for unloading of the left ventricle, the oxygenation level and cardiac function rapidly declined. Unexpectedly, an echocardiogram showed a right-to-left shunt (to-and-fro pattern) via PIVSD. By increasing the ECMO and decreasing Impella flow, the shunt flow changed to left-to-right, and oxygenation level and cardiac function improved. Ten days after ECMO was started, elective surgical repair was successfully performed. Conclusion: ECPELLA (ECMO + Impella) can offset the adverse effects of isolated ECMO support and reduce the PIVSD shunt flow. However, the risk of right-to-left shunt has not been reported, and ECPELLA caused a right-to-left shunt with deoxygenated systemic perfusion in the present case. A simulation study indicated that the right ventricular failure in PIVSD may pose a risk for right-to-left PIVSD shunt under Impella support. … (more)
- Is Part Of:
- European heart journal. Volume 5:Issue 8(2021)
- Journal:
- European heart journal
- Issue:
- Volume 5:Issue 8(2021)
- Issue Display:
- Volume 5, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 5
- Issue:
- 8
- Issue Sort Value:
- 2021-0005-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08-31
- Subjects:
- Post-myocardial infarction ventricular septal defect -- Mechanical circulatory support -- Extracorporeal membrane oxygenation -- Left ventricular assist device -- Impella
Cardiology -- Periodicals
Cardiology -- Case studies -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Case studies -- Periodicals
616.12 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/ehjcr/ ↗ - DOI:
- 10.1093/ehjcr/ytab209 ↗
- Languages:
- English
- ISSNs:
- 2514-2119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25878.xml