The Allegra transcatheter heart valve: Short term results from a multicenter registry. Issue 6 (17th June 2021)
- Record Type:
- Journal Article
- Title:
- The Allegra transcatheter heart valve: Short term results from a multicenter registry. Issue 6 (17th June 2021)
- Main Title:
- The Allegra transcatheter heart valve: Short term results from a multicenter registry
- Authors:
- Wolfrum, Mathias
Moccetti, Federico
Piuhola, Jarkko
Lehtola, Heidi
Baz, José Antonio
Iñiguez, Andrés
van Nunen, Lokien X.
Tonino, Pim A. L.
Niemelä, Matti
Toggweiler, Stefan - Abstract:
- Abstract: Objectives: We aimed to determine the safety and efficacy of the Allegra transcatheter heart valve (THV) for the treatment of severe aortic valve stenosis in a large patient population treated under real‐world conditions. Background: The Allegra is a novel self‐expanding THV with supra‐annular bovine leaflets. The valve is available in three different sizes (23, 27, and 31 mm), all are delivered through an 18F sheath. Methods: Consecutive patients undergoing TAVR with the Allegra THV were enrolled in a multicenter‐registry. Data were collected throughout initial hospital‐stay and at 30‐day follow‐up. Clinical endpoints were defined according to the updated definitions of the Valve‐Academic‐Research‐Consortium. Results: This registry included 255 patients (mean age 83 ± 6 years, 48% women) from four European centers. Median European System for Cardiac Operative Risk Evaluation II score (EuroSCORE II) was 3.3% (IQR 1.9–5.8%). Acute device success was 95.7%. The remaining 11 patients had either moderate paravalvular regurgitation immediately after the procedure (7 patients) or the device could not be optimal positioned requiring implantation of a second THV (4 patients). Major vascular complications and major/life‐threatening bleedings occurred in 10 (3.9%) and 12 (4.7%) patients, respectively. At 30 day follow‐up, mean effective orifice area was 2.2 ± 0.5 cm 2, mean gradient was 6.9 ± 3.8 mmHg, 7 (3.3%) patients had more than mild paravalvular leakage, 3 patientsAbstract: Objectives: We aimed to determine the safety and efficacy of the Allegra transcatheter heart valve (THV) for the treatment of severe aortic valve stenosis in a large patient population treated under real‐world conditions. Background: The Allegra is a novel self‐expanding THV with supra‐annular bovine leaflets. The valve is available in three different sizes (23, 27, and 31 mm), all are delivered through an 18F sheath. Methods: Consecutive patients undergoing TAVR with the Allegra THV were enrolled in a multicenter‐registry. Data were collected throughout initial hospital‐stay and at 30‐day follow‐up. Clinical endpoints were defined according to the updated definitions of the Valve‐Academic‐Research‐Consortium. Results: This registry included 255 patients (mean age 83 ± 6 years, 48% women) from four European centers. Median European System for Cardiac Operative Risk Evaluation II score (EuroSCORE II) was 3.3% (IQR 1.9–5.8%). Acute device success was 95.7%. The remaining 11 patients had either moderate paravalvular regurgitation immediately after the procedure (7 patients) or the device could not be optimal positioned requiring implantation of a second THV (4 patients). Major vascular complications and major/life‐threatening bleedings occurred in 10 (3.9%) and 12 (4.7%) patients, respectively. At 30 day follow‐up, mean effective orifice area was 2.2 ± 0.5 cm 2, mean gradient was 6.9 ± 3.8 mmHg, 7 (3.3%) patients had more than mild paravalvular leakage, 3 patients (1.2%) had died, 6 patients (2.4%) had a stroke and 30 (12.8%) patients had required implantation of a new permanent pacemaker. Conclusions: Transfemoral implantation of the Allegra THV resulted in favorable clinical and echocardiographic outcomes during hospitalization and short‐term follow up. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 98:Issue 6(2021)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 98:Issue 6(2021)
- Issue Display:
- Volume 98, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 98
- Issue:
- 6
- Issue Sort Value:
- 2021-0098-0006-0000
- Page Start:
- 1204
- Page End:
- 1209
- Publication Date:
- 2021-06-17
- Subjects:
- Allegra -- aortic stenosis -- transcatheter aortic valve -- TAVR -- transcatheter aortic valve replacement -- outcomes
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.29833 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25865.xml