Characterisation of blink dynamics using a high‐speed infrared imaging system. (26th May 2020)
- Record Type:
- Journal Article
- Title:
- Characterisation of blink dynamics using a high‐speed infrared imaging system. (26th May 2020)
- Main Title:
- Characterisation of blink dynamics using a high‐speed infrared imaging system
- Authors:
- Navascues‐Cornago, Maria
Morgan, Philip B
Maldonado‐Codina, Carole
Read, Michael L - Abstract:
- Abstract: Purpose: Development and validation of a non‐invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm. Methods: A pilot study investigated the influence of illumination type on blink dynamics. Spontaneous blinking was recorded in eight subjects using a high‐speed camera under two illumination conditions: white light and infrared. Custom semi‐automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration. The main clinical study compared two different image analysis techniques. Spontaneous blinking was recorded in 20 subjects using a high‐speed infrared camera. Blink speed and duration were determined using two techniques: manual tracking and semi‐automated tracking. Agreement between the two techniques was assessed using Bland‐Altman analysis. Coefficients of repeatability (COR) were calculated for the semi‐automated technique. Results: There were significant differences between white light and infrared illumination for PAH ( p < 0.0001), blink rate ( p = 0.04), closing speed ( p = 0.009), opening speed ( p < 0.0001) and blink duration ( p = 0.0003). The mean differences (95% limits of agreement) between the two techniques were 0.6 mm s −1 (−15.9 to 17.0) closing speed, 1.5 mm s −1 (−6.8 to 9.8) opening speed, 2.4 ms (−6.8 to 11.5) closed phase duration and 5.0 ms (−19.4 to 29.3) total blink duration. COR values were 10.1 mm s −1Abstract: Purpose: Development and validation of a non‐invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm. Methods: A pilot study investigated the influence of illumination type on blink dynamics. Spontaneous blinking was recorded in eight subjects using a high‐speed camera under two illumination conditions: white light and infrared. Custom semi‐automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration. The main clinical study compared two different image analysis techniques. Spontaneous blinking was recorded in 20 subjects using a high‐speed infrared camera. Blink speed and duration were determined using two techniques: manual tracking and semi‐automated tracking. Agreement between the two techniques was assessed using Bland‐Altman analysis. Coefficients of repeatability (COR) were calculated for the semi‐automated technique. Results: There were significant differences between white light and infrared illumination for PAH ( p < 0.0001), blink rate ( p = 0.04), closing speed ( p = 0.009), opening speed ( p < 0.0001) and blink duration ( p = 0.0003). The mean differences (95% limits of agreement) between the two techniques were 0.6 mm s −1 (−15.9 to 17.0) closing speed, 1.5 mm s −1 (−6.8 to 9.8) opening speed, 2.4 ms (−6.8 to 11.5) closed phase duration and 5.0 ms (−19.4 to 29.3) total blink duration. COR values were 10.1 mm s −1 closing speed, 3.7 mm s −1 opening speed, 6.7 ms closed phase duration and 11.2 ms total blink duration. Conclusions: This study has shown that spontaneous blinking can be characterised using a non‐invasive imaging system. The semi‐automated analysis provides a rapid characterisation of blink dynamics, allowing its application in large‐scale trials in a number of clinical areas. … (more)
- Is Part Of:
- Ophthalmic and physiological optics. Volume 40:Number 4(2020:Jul.)
- Journal:
- Ophthalmic and physiological optics
- Issue:
- Volume 40:Number 4(2020:Jul.)
- Issue Display:
- Volume 40, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 40
- Issue:
- 4
- Issue Sort Value:
- 2020-0040-0004-0000
- Page Start:
- 519
- Page End:
- 528
- Publication Date:
- 2020-05-26
- Subjects:
- blink speed -- eyelids -- image analysis -- infrared imaging -- non‐invasive -- spontaneous blinking
Ophthalmology -- Periodicals
Physiological optics -- Periodicals
Optometry -- Periodicals
Optics -- Periodicals
Vision -- Periodicals
617.75 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0275-5408&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/opo.12694 ↗
- Languages:
- English
- ISSNs:
- 0275-5408
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6270.870000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25876.xml