Optimizing the frame duration for data‐driven rigid motion estimation in brain PET imaging. Issue 6 (14th May 2021)
- Record Type:
- Journal Article
- Title:
- Optimizing the frame duration for data‐driven rigid motion estimation in brain PET imaging. Issue 6 (14th May 2021)
- Main Title:
- Optimizing the frame duration for data‐driven rigid motion estimation in brain PET imaging
- Authors:
- Spangler‐Bickell, Matthew G.
Hurley, Samuel A.
Deller, Timothy W.
Jansen, Floris
Bettinardi, Valentino
Carlson, Mackenzie
Zeineh, Michael
Zaharchuk, Greg
McMillan, Alan B. - Abstract:
- Abstract : Purpose: Data‐driven rigid motion estimation for PET brain imaging is usually performed using data frames sampled at low temporal resolution to reduce the overall computation time and to provide adequate signal‐to‐noise ratio in the frames. In recent work it has been demonstrated that list‐mode reconstructions of ultrashort frames are sufficient for motion estimation and can be performed very quickly. In this work we take the approach of using image‐based registration of reconstructions of very short frames for data‐driven motion estimation, and optimize a number of reconstruction and registration parameters (frame duration, MLEM iterations, image pixel size, post‐smoothing filter, reference image creation, and registration metric) to ensure accurate registrations while maximizing temporal resolution and minimizing total computation time. Methods: Data from 18 F‐fluorodeoxyglucose (FDG) and 18 F‐florbetaben (FBB) tracer studies with varying count rates are analyzed, for PET/MR and PET/CT scanners. For framed reconstructions using various parameter combinations interframe motion is simulated and image‐based registrations are performed to estimate that motion. Results: For FDG and FBB tracers using 4 × 10 5 true and scattered coincidence events per frame ensures that 95% of the registrations will be accurate to within 1 mm of the ground truth. This corresponds to a frame duration of 0.5–1 sec for typical clinical PET activity levels. Using four MLEM iterations withAbstract : Purpose: Data‐driven rigid motion estimation for PET brain imaging is usually performed using data frames sampled at low temporal resolution to reduce the overall computation time and to provide adequate signal‐to‐noise ratio in the frames. In recent work it has been demonstrated that list‐mode reconstructions of ultrashort frames are sufficient for motion estimation and can be performed very quickly. In this work we take the approach of using image‐based registration of reconstructions of very short frames for data‐driven motion estimation, and optimize a number of reconstruction and registration parameters (frame duration, MLEM iterations, image pixel size, post‐smoothing filter, reference image creation, and registration metric) to ensure accurate registrations while maximizing temporal resolution and minimizing total computation time. Methods: Data from 18 F‐fluorodeoxyglucose (FDG) and 18 F‐florbetaben (FBB) tracer studies with varying count rates are analyzed, for PET/MR and PET/CT scanners. For framed reconstructions using various parameter combinations interframe motion is simulated and image‐based registrations are performed to estimate that motion. Results: For FDG and FBB tracers using 4 × 10 5 true and scattered coincidence events per frame ensures that 95% of the registrations will be accurate to within 1 mm of the ground truth. This corresponds to a frame duration of 0.5–1 sec for typical clinical PET activity levels. Using four MLEM iterations with no subsets, a transaxial pixel size of 4 mm, a post‐smoothing filter with 4–6 mm full width at half maximum, and averaging two or more frames to create the reference image provides an optimal set of parameters to produce accurate registrations while keeping the reconstruction and processing time low. Conclusions: It is shown that very short frames (≤1 sec) can be used to provide accurate and quick data‐driven rigid motion estimates for use in an event‐by‐event motion corrected reconstruction. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 6(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 6(2021)
- Issue Display:
- Volume 48, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 6
- Issue Sort Value:
- 2021-0048-0006-0000
- Page Start:
- 3031
- Page End:
- 3041
- Publication Date:
- 2021-05-14
- Subjects:
- brain imaging -- data‐driven motion estimation -- list‐mode -- PET reconstruction -- rigid motion correction -- ultrashort frames
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14889 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25872.xml