Reoperation Rates of Percutaneous and Paddle Leads in Spinal Cord Stimulator Systems: A Single-Center Retrospective Analysis. Issue 1 (4th August 2020)
- Record Type:
- Journal Article
- Title:
- Reoperation Rates of Percutaneous and Paddle Leads in Spinal Cord Stimulator Systems: A Single-Center Retrospective Analysis. Issue 1 (4th August 2020)
- Main Title:
- Reoperation Rates of Percutaneous and Paddle Leads in Spinal Cord Stimulator Systems: A Single-Center Retrospective Analysis
- Authors:
- Antonovich, Devin D
Gama, Willy
Ritter, Alexandra
Wolf, Bethany Jacobs
Nobles, Ryan H
Selassie, Meron A
Hillegass, M Gabriel - Abstract:
- Abstract: Objective: We hypothesize that reoperation rates of spinal cord stimulation (SCS) systems utilizing percutaneous leads are comparable to those utilizing paddle leads. We attempt here to characterize causes for those reoperations and identify any related patient characteristics. Design and Subjects: This study is a single-center retrospective chart review of 291 subjects (410 operations) who underwent at least one permanent SCS implantation utilizing percutaneous or paddle leads over a 10-year period at the Medical University of South Carolina. Methods: Charts were reviewed for height, weight, body mass index, gender, race, age, stimulator type, type of reoperation, diabetes status, history and type of prior back surgery, top lead location, and number of leads placed. Comparisons of patient and procedural characteristics were conducted using a two-sample t test (continuous variables), chi-square, or Fisher exact approach (categorical variables). Univariate and multivariate Cox regression models were developed, identifying associations between patient characteristics, SCS characteristics, reoperation rates, and time to reoperation. Results: Thirty point five eight percent of subjects (89/291), required at least one reoperation. The reoperation rate was 27.84% for percutaneous systems (N = 54/194) and 27.78% for percutaneous systems (N = 60/216). Time to reoperation also did not differ between the two systems (hazard ratio [HR] = 1.06, 95% CI = 0.70–1.60). Of allAbstract: Objective: We hypothesize that reoperation rates of spinal cord stimulation (SCS) systems utilizing percutaneous leads are comparable to those utilizing paddle leads. We attempt here to characterize causes for those reoperations and identify any related patient characteristics. Design and Subjects: This study is a single-center retrospective chart review of 291 subjects (410 operations) who underwent at least one permanent SCS implantation utilizing percutaneous or paddle leads over a 10-year period at the Medical University of South Carolina. Methods: Charts were reviewed for height, weight, body mass index, gender, race, age, stimulator type, type of reoperation, diabetes status, history and type of prior back surgery, top lead location, and number of leads placed. Comparisons of patient and procedural characteristics were conducted using a two-sample t test (continuous variables), chi-square, or Fisher exact approach (categorical variables). Univariate and multivariate Cox regression models were developed, identifying associations between patient characteristics, SCS characteristics, reoperation rates, and time to reoperation. Results: Thirty point five eight percent of subjects (89/291), required at least one reoperation. The reoperation rate was 27.84% for percutaneous systems (N = 54/194) and 27.78% for percutaneous systems (N = 60/216). Time to reoperation also did not differ between the two systems (hazard ratio [HR] = 1.06, 95% CI = 0.70–1.60). Of all factors examined, younger age at time of placement was the only factor associated with risk of reoperation (HR = 0.73, 95% CI = 0.62–0.87, P < 0.001). Conclusions: Our data suggest that reoperation rates and time to reoperation between percutaneous and paddle leads are clinically similar; therefore, rates of reoperation should have no bearing on which system to choose. … (more)
- Is Part Of:
- Pain medicine. Volume 22:Issue 1(2021)
- Journal:
- Pain medicine
- Issue:
- Volume 22:Issue 1(2021)
- Issue Display:
- Volume 22, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2021-0022-0001-0000
- Page Start:
- 34
- Page End:
- 40
- Publication Date:
- 2020-08-04
- Subjects:
- Spinal Cord Stimulation -- Paddle Leads -- Percutaneous Leads -- Lead Revisions -- Spinal Cord Stimulator Complications -- Spinal Cord Stimulator Revisions
Pain -- Periodicals
Pain -- Treatment -- Periodicals
Analgesics -- Periodicals
Pain -- Periodicals
Pain Management -- Periodicals
Douleur -- Périodiques
Douleur -- Traitement -- Périodiques
Analgésiques -- Périodiques
Analgésique
Soulagement de la douleur
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.047205 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1526-2375;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1526-4637 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=pme ↗
http://painmedicine.oxfordjournals.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1093/pm/pnaa215 ↗
- Languages:
- English
- ISSNs:
- 1526-2375
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6333.806000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25858.xml