Blood flow energy loss: a predictor for the recovery of left ventricular function after bioprosthetic aortic valve replacement. (8th May 2021)
- Record Type:
- Journal Article
- Title:
- Blood flow energy loss: a predictor for the recovery of left ventricular function after bioprosthetic aortic valve replacement. (8th May 2021)
- Main Title:
- Blood flow energy loss: a predictor for the recovery of left ventricular function after bioprosthetic aortic valve replacement
- Authors:
- Hohri, Yu
Itatani, Keiichi
Numata, Satoshi
Yamazaki, Sachiko
Miyazaki, Shohei
Nishino, Teruyasu
Yaku, Hitoshi - Abstract:
- Abstract: : OBJECTIVES: It is difficult to estimate the improvement in left ventricular (LV) function after aortic valve replacement (AVR). The present study aimed to evaluate whether energy loss (EL) can predict the postoperative LV function after AVR. METHODS: Nine patients who underwent AVR with a bioprosthetic valve were enrolled in the present study. Porcine prostheses were used in 5 patients and bovine pericardial prostheses were used in 4 patients. The aortic flow pattern was visualized and EL and cardiac output (CO) were measured using 4-dimensional flow magnetic resonance imaging from the LV to the descending aorta; the EL/CO ratio in the extracted area was calculated as total EL/CO ratio. RESULTS: With a porcine valve, a severe helical flow was observed in the ascending aorta during the holosystolic phase. In contrast, with a bovine pericardial valve, straight transvalvular aortic flow was observed in the early systolic phase and 2 large vortical flows occurred on both sides of the greater and lesser curvature of the ascending aorta after the mid-systolic period. The total EL/CO ratio was strongly correlated with LV ejection fraction improvement after AVR ( r = 0.74, P = 0.02). CONCLUSIONS: The aortic flow pattern is different between the porcine valve and bovine pericardial valve. The total EL/CO ratio is a valuable tool for evaluating the postoperative LV ejection fraction improvement after AVR. Optimization of total EL/CO ratio would have potential to improveAbstract: : OBJECTIVES: It is difficult to estimate the improvement in left ventricular (LV) function after aortic valve replacement (AVR). The present study aimed to evaluate whether energy loss (EL) can predict the postoperative LV function after AVR. METHODS: Nine patients who underwent AVR with a bioprosthetic valve were enrolled in the present study. Porcine prostheses were used in 5 patients and bovine pericardial prostheses were used in 4 patients. The aortic flow pattern was visualized and EL and cardiac output (CO) were measured using 4-dimensional flow magnetic resonance imaging from the LV to the descending aorta; the EL/CO ratio in the extracted area was calculated as total EL/CO ratio. RESULTS: With a porcine valve, a severe helical flow was observed in the ascending aorta during the holosystolic phase. In contrast, with a bovine pericardial valve, straight transvalvular aortic flow was observed in the early systolic phase and 2 large vortical flows occurred on both sides of the greater and lesser curvature of the ascending aorta after the mid-systolic period. The total EL/CO ratio was strongly correlated with LV ejection fraction improvement after AVR ( r = 0.74, P = 0.02). CONCLUSIONS: The aortic flow pattern is different between the porcine valve and bovine pericardial valve. The total EL/CO ratio is a valuable tool for evaluating the postoperative LV ejection fraction improvement after AVR. Optimization of total EL/CO ratio would have potential to improve haemodynamic performances after AVR. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 33:Number 3(2021)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 33:Number 3(2021)
- Issue Display:
- Volume 33, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 3
- Issue Sort Value:
- 2021-0033-0003-0000
- Page Start:
- 339
- Page End:
- 347
- Publication Date:
- 2021-05-08
- Subjects:
- Blood flow imaging -- 4-Dimensional flow magnetic resonance imaging -- Aortic valve replacement -- Energy loss -- Bioprosthetic prosthesis
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivab094 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25852.xml