Rotational thromboelastometry for diagnosis of fibrinolysis induced by urokinase in an in-vitro model. Issue 1 (January 2022)
- Record Type:
- Journal Article
- Title:
- Rotational thromboelastometry for diagnosis of fibrinolysis induced by urokinase in an in-vitro model. Issue 1 (January 2022)
- Main Title:
- Rotational thromboelastometry for diagnosis of fibrinolysis induced by urokinase in an in-vitro model
- Authors:
- Bevilacqua, Sergio
Paniccia, Rita
Galeotti, Ilaria
Viappiani, Anna
Dimizio, Fabio
Bartolozzi, Carlo
Marcucci, Rossella
Stefàno, Pierluigi - Abstract:
- Abstract : N/A: Fibrinolysis can be abnormally activated in several critical care settings but it's often misdiagnosed by standard laboratory tests. Although rotational thromboelastometry can assess the whole coagulative process, its ability to detect fibrinolysis has been questioned. Aim of this study was to investigate the ability of thromboelastometry in detecting induced fibrinolysis in an in-vitro model. Whole blood samples were taken from 18 healthy volunteers. Each sample was split and added with increasing urokinase concentrations till to reach 0, 50, 75 and 100 IU/ml. Thromboelastometry tests, extem and aptem, were performed on the obtained samples. If significant lysis at 50 IU/ml was recorded, also 10, 25 and 35 IU/ml drug concentrations were tested. No lytic effects were detected in 10 IU/ml samples. Lysis variables were the most sensitive in detecting fibrinolysis even at 25 IU/ml ( P < 0.05). Clot firmness parameters were also affected by urokinase, but only at the two highest drug concentrations ( P < 0.05). Extem/aptem ratio enhanced the sensitivity of these parameters only if lysis was more marked. Analysing groups of different lysis severity, the time to achieve maximum clot firmness could anticipate an ongoing fulminant or intermediate lysis with 100% sensitivity and 100% specificity ( P < 0.05) when lower than 1341.5 s. Rotational thromboelastometry could detect fibrinolysis when it was induced in vitro by 25 IU/ml urokinase or more. Apart from theAbstract : N/A: Fibrinolysis can be abnormally activated in several critical care settings but it's often misdiagnosed by standard laboratory tests. Although rotational thromboelastometry can assess the whole coagulative process, its ability to detect fibrinolysis has been questioned. Aim of this study was to investigate the ability of thromboelastometry in detecting induced fibrinolysis in an in-vitro model. Whole blood samples were taken from 18 healthy volunteers. Each sample was split and added with increasing urokinase concentrations till to reach 0, 50, 75 and 100 IU/ml. Thromboelastometry tests, extem and aptem, were performed on the obtained samples. If significant lysis at 50 IU/ml was recorded, also 10, 25 and 35 IU/ml drug concentrations were tested. No lytic effects were detected in 10 IU/ml samples. Lysis variables were the most sensitive in detecting fibrinolysis even at 25 IU/ml ( P < 0.05). Clot firmness parameters were also affected by urokinase, but only at the two highest drug concentrations ( P < 0.05). Extem/aptem ratio enhanced the sensitivity of these parameters only if lysis was more marked. Analysing groups of different lysis severity, the time to achieve maximum clot firmness could anticipate an ongoing fulminant or intermediate lysis with 100% sensitivity and 100% specificity ( P < 0.05) when lower than 1341.5 s. Rotational thromboelastometry could detect fibrinolysis when it was induced in vitro by 25 IU/ml urokinase or more. Apart from the parameters specific for lysis, time to achieve maximum clot firmness appeared as the earliest indicator of fibrinolysis with high sensitivity and specificity especially if a more intense lysis was going on. … (more)
- Is Part Of:
- Blood coagulation and fibrinolysis. Volume 33:Issue 1(2022)
- Journal:
- Blood coagulation and fibrinolysis
- Issue:
- Volume 33:Issue 1(2022)
- Issue Display:
- Volume 33, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2022-0033-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01
- Subjects:
- blood coagulation disorders -- fibrinolysis -- point-of-care systems -- thromboelastometry -- urokinase-type plasminogen activator
Blood -- Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
Blood Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
612.115 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00001721-000000000-00000 ↗
http://www.bloodcoagulation.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBC.0000000000001102 ↗
- Languages:
- English
- ISSNs:
- 0957-5235
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2112.650000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25851.xml