The impact of implantable cardioverter-defibrillator implantation on health-related quality of life in the DANISH trial. Issue 6 (22nd February 2019)
- Record Type:
- Journal Article
- Title:
- The impact of implantable cardioverter-defibrillator implantation on health-related quality of life in the DANISH trial. Issue 6 (22nd February 2019)
- Main Title:
- The impact of implantable cardioverter-defibrillator implantation on health-related quality of life in the DANISH trial
- Authors:
- Bundgaard, Johan S
Thune, Jens J
Nielsen, Jens C
Videbæk, Regitze
Haarbo, Jens
Bruun, Niels E
Videbæk, Lars
Aagaard, David
Korup, Eva
Jensen, Gunnar
Hildebrandt, Per
Steffensen, Flemming H
Eiskjær, Hans
Brandes, Axel
Thøgersen, Anna M
Melchior, Thomas M
Pedersen, Ole D
Gustafsson, Finn
Egstrup, Kenneth
Hassager, Christian
Svendsen, Jesper H
Høfsten, Dan E
Torp-Pedersen, Christian
Pedersen, Susanne S
Pehrson, Steen
Køber, Lars
Mogensen, Ulrik M - Abstract:
- Abstract: Aim: The Danish Study to Assess the Efficacy of Implantable Cardioverter-Defibrillators (ICD) in Patients with Non-ischaemic Systolic Heart Failure (HF) on Mortality (DANISH) found no overall effect on all-cause mortality. The effect of ICD implantation on health-related quality of life (HRQoL) remains to be established as previous trials have demonstrated conflicting results. We investigated the impact of ICD implantation on HRQoL in patients with non-ischaemic systolic HF, a prespecified secondary endpoint in DANISH. Methods and results: In DANISH, a total of 1116 patients with non-ischaemic systolic HF were randomly assigned (1:1) to ICD implantation or usual clinical care (control). Patients completed disease-specific HRQoL as assessed by Minnesota Living with Heart Failure Questionnaire (MLHFQ; 0–105, high indicating worse). Changes in HRQoL 8 months after randomization were assessed with a mixed-effects model. At randomization, MLHFQ was completed by 935 (84%) patients ( n = 472 in the ICD group and n = 463 in the control group) and was reassessed in 274 (58%) and 292 (63%) patients, respectively after 8 months for the primary analysis. Patients in the ICD group vs. the control group had similar improvements in MLHFQ after 8 months [least square mean −7.0 vs. −4.2 ( P = 0.13)]. A clinically relevant improvement (decrease ≥5) in the MLHFQ overall score at 8 months was observed in 151 patients in the ICD group and 148 patients in the control group [55% vs.Abstract: Aim: The Danish Study to Assess the Efficacy of Implantable Cardioverter-Defibrillators (ICD) in Patients with Non-ischaemic Systolic Heart Failure (HF) on Mortality (DANISH) found no overall effect on all-cause mortality. The effect of ICD implantation on health-related quality of life (HRQoL) remains to be established as previous trials have demonstrated conflicting results. We investigated the impact of ICD implantation on HRQoL in patients with non-ischaemic systolic HF, a prespecified secondary endpoint in DANISH. Methods and results: In DANISH, a total of 1116 patients with non-ischaemic systolic HF were randomly assigned (1:1) to ICD implantation or usual clinical care (control). Patients completed disease-specific HRQoL as assessed by Minnesota Living with Heart Failure Questionnaire (MLHFQ; 0–105, high indicating worse). Changes in HRQoL 8 months after randomization were assessed with a mixed-effects model. At randomization, MLHFQ was completed by 935 (84%) patients ( n = 472 in the ICD group and n = 463 in the control group) and was reassessed in 274 (58%) and 292 (63%) patients, respectively after 8 months for the primary analysis. Patients in the ICD group vs. the control group had similar improvements in MLHFQ after 8 months [least square mean −7.0 vs. −4.2 ( P = 0.13)]. A clinically relevant improvement (decrease ≥5) in the MLHFQ overall score at 8 months was observed in 151 patients in the ICD group and 148 patients in the control group [55% vs. 51%, respectively ( P = 0.25)]. Conclusion: Implantable cardioverter-defibrillator implantation in patients with non-ischaemic systolic HF did not significantly alter HRQoL compared with patients randomized to usual clinical care. … (more)
- Is Part Of:
- Europace. Volume 21:Issue 6(2019)
- Journal:
- Europace
- Issue:
- Volume 21:Issue 6(2019)
- Issue Display:
- Volume 21, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 6
- Issue Sort Value:
- 2019-0021-0006-0000
- Page Start:
- 900
- Page End:
- 908
- Publication Date:
- 2019-02-22
- Subjects:
- Quality of life -- Heart failure -- Implantable cardioverter-defibrillator -- Cardiovascular disease
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euz018 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25847.xml