Calibration of the PlusOptix PowerRef 3 with change in viewing distance, adult age and refractive error. (24th June 2019)
- Record Type:
- Journal Article
- Title:
- Calibration of the PlusOptix PowerRef 3 with change in viewing distance, adult age and refractive error. (24th June 2019)
- Main Title:
- Calibration of the PlusOptix PowerRef 3 with change in viewing distance, adult age and refractive error
- Authors:
- Ghahghaei, Saeideh
Reed, Olivia
Candy, T Rowan
Chandna, Arvind - Abstract:
- Abstract: Purpose: The PowerRef 3 is frequently used in studying the near triad of accommodation, vergence and pupil responses in normal and clinical populations. Within a range, the defocus measurement of the PowerRef 3 is linearly related to the eye's defocus. While the default factory‐calibrated slope of this relation (calibration factor) is 1, it has been shown that the slope can vary across individuals. Here, we addressed the impact of changes in viewing distance, age and defocus of the eye on the calibration factor. Methods: We manipulated viewing distance (40 cm, 1 m and 6 m) and recruited participants with a range of accommodative capabilities: participants in their 20s, 40s and over 60 years old. To test whether any effect was larger than the range of measurement reliability of the instrument, we collected data for each condition four times: two in the same session, another on the same day, and one on a different day. Results: The results demonstrated that viewing distance did not affect the calibration factor over the linear range, regardless of age or uncorrected refractive error. The largest proportion of the variance was explained by between‐subject differences. Conclusions: Calibration data for the PowerRef 3 were not sensitive to changes in viewing distance. Nevertheless, our results re‐emphasise the relevance of calibration for studies of individual participants.
- Is Part Of:
- Ophthalmic and physiological optics. Volume 39:Number 4(2019:Jul.)
- Journal:
- Ophthalmic and physiological optics
- Issue:
- Volume 39:Number 4(2019:Jul.)
- Issue Display:
- Volume 39, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 39
- Issue:
- 4
- Issue Sort Value:
- 2019-0039-0004-0000
- Page Start:
- 253
- Page End:
- 259
- Publication Date:
- 2019-06-24
- Subjects:
- accommodation -- eccentric photorefraction -- PowerRefractor
Ophthalmology -- Periodicals
Physiological optics -- Periodicals
Optometry -- Periodicals
Optics -- Periodicals
Vision -- Periodicals
617.75 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0275-5408&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/opo.12631 ↗
- Languages:
- English
- ISSNs:
- 0275-5408
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6270.870000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25848.xml