Objective measurement of spectacle wear with a temperature sensor data logger. (8th November 2017)
- Record Type:
- Journal Article
- Title:
- Objective measurement of spectacle wear with a temperature sensor data logger. (8th November 2017)
- Main Title:
- Objective measurement of spectacle wear with a temperature sensor data logger
- Authors:
- Lentsch, Matthew J.
Marsack, Jason D.
Anderson, Heather A. - Abstract:
- Abstract: Purpose: This study seeks to establish the utility of the SmartButton Data Logger (www.acrsystems.com ) to monitor spectacle wear for research and clinical applications. Methods: Fifty adults wore a thermosensor on their spectacles for 2 weeks for each of two mount types while keeping wear‐time logs. Temperatures during reported spectacle wear (ON) were compared to temperatures during non‐wear (OFF) with repeated measures analysis of variance (ANOVA). In addition, two strategies to approximate spectacle wear from temperature data were evaluated: (1) Filtering data based on temperature ranges to identify spectacle wear (either group mean ON temperature, or an individual's mean ON temperature), and (2) Separate examiners inspecting temperature against time plots to identify spectacle wear. The success of these methods to approximate wear time was evaluated by per cent error with respect to subject reported wear time. Results: Group mean ON (31.8 [0.6]°Celsius [°C]) and OFF (24.7 [1.5]°C) temperatures differed significantly ( F 1, 47 = 471.2, p < 0.001), but there was no difference in temperature between mounts ( F 1, 47 = 1.9, p = 0.18). Median per cent error and first and third quartiles (Q1, Q3) of each technique used to approximate wear time were: group mean filtering = 8% (Q1 3%, Q3 18%), individual mean filtering = 7% (Q1 4%, Q3 19%), Examiner 1 = 6% (Q1 2%, Q3 14%), Examiner 2 = 7% (Q1 3%, Q3 12%). Conclusions: The SmartButton can monitor spectacleAbstract: Purpose: This study seeks to establish the utility of the SmartButton Data Logger (www.acrsystems.com ) to monitor spectacle wear for research and clinical applications. Methods: Fifty adults wore a thermosensor on their spectacles for 2 weeks for each of two mount types while keeping wear‐time logs. Temperatures during reported spectacle wear (ON) were compared to temperatures during non‐wear (OFF) with repeated measures analysis of variance (ANOVA). In addition, two strategies to approximate spectacle wear from temperature data were evaluated: (1) Filtering data based on temperature ranges to identify spectacle wear (either group mean ON temperature, or an individual's mean ON temperature), and (2) Separate examiners inspecting temperature against time plots to identify spectacle wear. The success of these methods to approximate wear time was evaluated by per cent error with respect to subject reported wear time. Results: Group mean ON (31.8 [0.6]°Celsius [°C]) and OFF (24.7 [1.5]°C) temperatures differed significantly ( F 1, 47 = 471.2, p < 0.001), but there was no difference in temperature between mounts ( F 1, 47 = 1.9, p = 0.18). Median per cent error and first and third quartiles (Q1, Q3) of each technique used to approximate wear time were: group mean filtering = 8% (Q1 3%, Q3 18%), individual mean filtering = 7% (Q1 4%, Q3 19%), Examiner 1 = 6% (Q1 2%, Q3 14%), Examiner 2 = 7% (Q1 3%, Q3 12%). Conclusions: The SmartButton can monitor spectacle compliance in patients with all approximation methods evaluated providing less than 10% median per cent error in wear time. … (more)
- Is Part Of:
- Ophthalmic and physiological optics. Volume 38:Number 1(2018:Jan.)
- Journal:
- Ophthalmic and physiological optics
- Issue:
- Volume 38:Number 1(2018:Jan.)
- Issue Display:
- Volume 38, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2018-0038-0001-0000
- Page Start:
- 37
- Page End:
- 47
- Publication Date:
- 2017-11-08
- Subjects:
- amblyopia -- dose monitoring -- objective monitoring -- spectacle compliance -- thermosensor
Ophthalmology -- Periodicals
Physiological optics -- Periodicals
Optometry -- Periodicals
Optics -- Periodicals
Vision -- Periodicals
617.75 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0275-5408&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/opo.12423 ↗
- Languages:
- English
- ISSNs:
- 0275-5408
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6270.870000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25852.xml