Simultaneous assessment of coronary stenosis relevance with automated computed tomography angiography and intravascular ultrasound analyses and fractional flow reserve. Issue 1 (January 2022)
- Record Type:
- Journal Article
- Title:
- Simultaneous assessment of coronary stenosis relevance with automated computed tomography angiography and intravascular ultrasound analyses and fractional flow reserve. Issue 1 (January 2022)
- Main Title:
- Simultaneous assessment of coronary stenosis relevance with automated computed tomography angiography and intravascular ultrasound analyses and fractional flow reserve
- Authors:
- Blanco, Pablo J.
Bulant, Carlos A.
Bezerra, Cristiano Guedes
Lemos, Pedro A.
García-García, Hector M. - Abstract:
- Abstract : Objectives: To assess the diagnostic performance of computed tomography angiography (CTA) and intravascular ultrasound (IVUS) derived minimum lumen areas (MLA) from the same lesions that correspond to an FFR ⩽0.80. Methods and results: A total of 24 patients (33 arteries) were collected retrospectively according to the following inclusion criteria: presence of a CTA diagnostic followed by an IVUS and FFR percutaneous coronary procedures. CTA and IVUS lumen contours were automatically performed using previously validated methods. The correlation between CTA and IVUS for the MLA was r = 0.45. In terms of MLA, the mean difference between CTA and IVUS was 0.81 mm 2 . Of note, a much smaller CTA-derived MLA (2.10 mm 2 ) was found to be related to significant FFR lesions compared to that of the MLA derived from IVUS (3.19 mm 2 ). The area under the curve, accuracy, sensitivity and specificity for this CTA-derived MLA were 0.80, 0.76, 0.50 and 0.87, respectively, while these values for IVUS-derived MLA were 0.87, 0.85, 0.80 and 0.87. Conclusions: Computed tomography angiography and intravascular ultrasound-derived minimum lumen areas have moderate diagnostic efficiency, albeit slightly better for IVUS, in identifying hemodynamically severe coronary stenoses. The utility of MLA, automatically derived from either CTA or IVUS as an alternative to FFR to guide the decision to revascularize, should be tested clinically. Abstract : Supplemental Digital Content is available inAbstract : Objectives: To assess the diagnostic performance of computed tomography angiography (CTA) and intravascular ultrasound (IVUS) derived minimum lumen areas (MLA) from the same lesions that correspond to an FFR ⩽0.80. Methods and results: A total of 24 patients (33 arteries) were collected retrospectively according to the following inclusion criteria: presence of a CTA diagnostic followed by an IVUS and FFR percutaneous coronary procedures. CTA and IVUS lumen contours were automatically performed using previously validated methods. The correlation between CTA and IVUS for the MLA was r = 0.45. In terms of MLA, the mean difference between CTA and IVUS was 0.81 mm 2 . Of note, a much smaller CTA-derived MLA (2.10 mm 2 ) was found to be related to significant FFR lesions compared to that of the MLA derived from IVUS (3.19 mm 2 ). The area under the curve, accuracy, sensitivity and specificity for this CTA-derived MLA were 0.80, 0.76, 0.50 and 0.87, respectively, while these values for IVUS-derived MLA were 0.87, 0.85, 0.80 and 0.87. Conclusions: Computed tomography angiography and intravascular ultrasound-derived minimum lumen areas have moderate diagnostic efficiency, albeit slightly better for IVUS, in identifying hemodynamically severe coronary stenoses. The utility of MLA, automatically derived from either CTA or IVUS as an alternative to FFR to guide the decision to revascularize, should be tested clinically. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Coronary artery disease. Volume 33:Issue 1(2022)
- Journal:
- Coronary artery disease
- Issue:
- Volume 33:Issue 1(2022)
- Issue Display:
- Volume 33, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2022-0033-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01
- Subjects:
- computed tomography angiography -- intravascular ultrasound -- fractional flow reserve -- coronary artery disease
Coronary heart disease -- Periodicals
Coronary Disease -- Indexes
Coronary Disease -- Periodicals
616.123005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00019501-000000000-00000 ↗
http://www.coronary-artery.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MCA.0000000000001044 ↗
- Languages:
- English
- ISSNs:
- 0954-6928
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3472.049000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25847.xml