Correspondence of CSF biomarkers measured by Lumipulse assays with amyloid PET. (31st December 2021)
- Record Type:
- Journal Article
- Title:
- Correspondence of CSF biomarkers measured by Lumipulse assays with amyloid PET. (31st December 2021)
- Main Title:
- Correspondence of CSF biomarkers measured by Lumipulse assays with amyloid PET
- Authors:
- Volluz, Katherine E.
Schindler, Suzanne E.
Henson, Rachel L.
Xiong, Chengjie
Gordon, Brian A.
Benzinger, Tammie L.S.
Holtzman, David M.
Morris, John C.
Fagan, Anne M. - Abstract:
- Abstract: Background: Traditional plate‐based assays for cerebrospinal fluid (CSF) biomarkers have been limited by relatively high assay variance that reduces the accuracy of individual measurements. Next generation automated assay platforms for CSF biomarkers reduce the variability of measurements, including across sample runs. In the current study, we utilized the Lumipulse G1200 (Fujirebio; Malvern, PA), a fully‐automated assay platform to compare CSF biomarkers to brain amyloid burden as determined by positron emission tomography (PET) imaging. Method: Participants (n=758) were enrolled in studies of memory and aging at the Knight ADRC in St. Louis, Missouri. Concentrations of CSF amyloid‐beta 40 (Aβ40), amyloid‐beta 42 (Aβ42), total tau (tTau) and phosphorylated tau‐181 (pTau) were measured using the Lumipulse G1200 automated assay system. Brain amyloid burden was measured via amyloid PET imaging using Florbetapir or Pittsburgh compound B (PIB). The correspondence of CSF biomarkers with amyloid PET status based on established cut‐offs for each radiotracer was evaluated. Result: For pooled CSF controls representing a range of three values (low, medium, high), coefficients for inter‐day variability ranged from 2‐4%. CSF collected within two years of an amyloid PET scan was evaluated from 521 amyloid PET‐negative and 237 amyloid PET‐positive individuals. Correspondence with amyloid PET by receiver operating characteristic (ROC) area under the curve (AUC) was highest forAbstract: Background: Traditional plate‐based assays for cerebrospinal fluid (CSF) biomarkers have been limited by relatively high assay variance that reduces the accuracy of individual measurements. Next generation automated assay platforms for CSF biomarkers reduce the variability of measurements, including across sample runs. In the current study, we utilized the Lumipulse G1200 (Fujirebio; Malvern, PA), a fully‐automated assay platform to compare CSF biomarkers to brain amyloid burden as determined by positron emission tomography (PET) imaging. Method: Participants (n=758) were enrolled in studies of memory and aging at the Knight ADRC in St. Louis, Missouri. Concentrations of CSF amyloid‐beta 40 (Aβ40), amyloid‐beta 42 (Aβ42), total tau (tTau) and phosphorylated tau‐181 (pTau) were measured using the Lumipulse G1200 automated assay system. Brain amyloid burden was measured via amyloid PET imaging using Florbetapir or Pittsburgh compound B (PIB). The correspondence of CSF biomarkers with amyloid PET status based on established cut‐offs for each radiotracer was evaluated. Result: For pooled CSF controls representing a range of three values (low, medium, high), coefficients for inter‐day variability ranged from 2‐4%. CSF collected within two years of an amyloid PET scan was evaluated from 521 amyloid PET‐negative and 237 amyloid PET‐positive individuals. Correspondence with amyloid PET by receiver operating characteristic (ROC) area under the curve (AUC) was highest for ratios including Aβ42: pTau/Aβ42 (0.97, 95% confidence intervals 0.96‐0.99), Aβ42/Aβ40 (0.97, 0.95‐0.98), and tTau/Aβ42 (0.96, 0.94‐0.97). A CSF pTau/Aβ42 value of >0.0649 had the highest combined positive and negative percent agreement (PPA of 0.91, 0.86‐0.94; NPA of 0.96, 0.93‐0.97) with amyloid PET status. The CSF value for Aβ42/Aβ40 with highest combined PPA and NPA was slightly more sensitive but less specific: <0.0673 had a PPA of 0.97 (0.94‐0.99) and NPA of 0.91 (0.88‐0.93) with amyloid PET status. Conclusion: Measurement of CSF biomarkers with the Lumipulse G1200 automated assay system was highly precise, with low variability over multiple runs. Values for pTau/Aβ42, Aβ42/Aβ40, and tTau/Aβ42 were highly concordant with amyloid PET status. … (more)
- Is Part Of:
- Alzheimer's & dementia. Volume 17(2021)Supplement 5
- Journal:
- Alzheimer's & dementia
- Issue:
- Volume 17(2021)Supplement 5
- Issue Display:
- Volume 17, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 17
- Issue:
- 5
- Issue Sort Value:
- 2021-0017-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-12-31
- Subjects:
- Alzheimer's disease -- Periodicals
Alzheimer Disease -- Periodicals
Dementia -- Periodicals
Démence
Maladie d'Alzheimer
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.83 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15525260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1002/alz.051085 ↗
- Languages:
- English
- ISSNs:
- 1552-5260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0806.255333
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25828.xml