The Accuracy of Three-Dimensional CT Scan Software in Predicting Prosthetic Utilization in Total Shoulder Arthroplasty. Issue 2 (15th January 2022)
- Record Type:
- Journal Article
- Title:
- The Accuracy of Three-Dimensional CT Scan Software in Predicting Prosthetic Utilization in Total Shoulder Arthroplasty. Issue 2 (15th January 2022)
- Main Title:
- The Accuracy of Three-Dimensional CT Scan Software in Predicting Prosthetic Utilization in Total Shoulder Arthroplasty
- Authors:
- Baumgarten, Keith M.
Radtke, Logan - Abstract:
- Abstract : Introduction: Recent innovations in shoulder arthroplasty include three-dimensional (3D) CT software imaging that can be used to predict which prosthetic implants will be used intraoperatively. Correct prediction of the implants may optimize supply chain logistics for the surgeon, hospital, ambulatory surgery center, and the implant company. The purpose of this study was to examine a single surgeon's experience with this software to determine its predictive accuracy in determining which implants would be used intraoperatively. Methods: A retrospective review of patients undergoing total shoulder arthroplasty (TSA) performed by a single surgeon was performed. Inclusion criteria were patients undergoing anatomic (aTSA) or reverse (rTSA) TSA examined preoperatively with the 3D CT planning software. A chart review was performed to compare the accuracy of the preoperative plan in predicting the actual prostheses implanted at surgery. Results: Two hundred seventy-eight shoulders from 260 patients were included. One hundred fifty-one shoulders underwent aTSA, and 127 shoulders underwent rTSA. The surgeon was able to predict the type of arthroplasty (anatomic versus reverse) implanted in 269 of 278 (97%) shoulders. Using the 3D CT software, the surgeon was able to predict all the implants implanted in 68 shoulders (24%). For aTSA, 3D CT imaging successfully predicted all implants implanted in 43 shoulders (28%), glenoid implants implanted in 120 of 148 shoulders (81%),Abstract : Introduction: Recent innovations in shoulder arthroplasty include three-dimensional (3D) CT software imaging that can be used to predict which prosthetic implants will be used intraoperatively. Correct prediction of the implants may optimize supply chain logistics for the surgeon, hospital, ambulatory surgery center, and the implant company. The purpose of this study was to examine a single surgeon's experience with this software to determine its predictive accuracy in determining which implants would be used intraoperatively. Methods: A retrospective review of patients undergoing total shoulder arthroplasty (TSA) performed by a single surgeon was performed. Inclusion criteria were patients undergoing anatomic (aTSA) or reverse (rTSA) TSA examined preoperatively with the 3D CT planning software. A chart review was performed to compare the accuracy of the preoperative plan in predicting the actual prostheses implanted at surgery. Results: Two hundred seventy-eight shoulders from 260 patients were included. One hundred fifty-one shoulders underwent aTSA, and 127 shoulders underwent rTSA. The surgeon was able to predict the type of arthroplasty (anatomic versus reverse) implanted in 269 of 278 (97%) shoulders. Using the 3D CT software, the surgeon was able to predict all the implants implanted in 68 shoulders (24%). For aTSA, 3D CT imaging successfully predicted all implants implanted in 43 shoulders (28%), glenoid implants implanted in 120 of 148 shoulders (81%), and humeral implants implanted in 54 shoulders (36%). For rTSA, 3D CT imaging successfully predicted all implants implanted in 26 shoulders (20%), glenoid implants implanted in 106 shoulders (83%), and humeral implants implanted in 39 shoulders (31%). Conclusions: The 3D CT software combined with surgeon's judgment provided a high accuracy (97%) in determining the type of arthroplasty, a moderately high accuracy in determining the glenoid implants (81% to 83%), a low accuracy in determining humeral implants (31% to 36%), and a low accuracy in determining all prostheses used for each surgery (20% to 28%). Level of Evidence: LOE IV—Diagnostic Case Series … (more)
- Is Part Of:
- Journal of the American Academy of Orthopaedic Surgeons. Volume 30:Issue 2(2022)
- Journal:
- Journal of the American Academy of Orthopaedic Surgeons
- Issue:
- Volume 30:Issue 2(2022)
- Issue Display:
- Volume 30, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 30
- Issue:
- 2
- Issue Sort Value:
- 2022-0030-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01-15
- Subjects:
- Orthopedics -- Periodicals
Orthopedic surgery -- Periodicals
Joint Diseases -- Periodicals
Orthopedics -- Periodicals
Orthopedic surgery
Orthopedics
Periodicals
616.7005 - Journal URLs:
- http://www.jaaos.org/ ↗
https://www.lww.co.uk ↗ - DOI:
- 10.5435/JAAOS-D-21-00641 ↗
- Languages:
- English
- ISSNs:
- 1067-151X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4683.732000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25827.xml