False lumen enhancement characteristics on computed tomography angiography predict risk of aneurysm formation in acute type B aortic dissection. (8th May 2021)
- Record Type:
- Journal Article
- Title:
- False lumen enhancement characteristics on computed tomography angiography predict risk of aneurysm formation in acute type B aortic dissection. (8th May 2021)
- Main Title:
- False lumen enhancement characteristics on computed tomography angiography predict risk of aneurysm formation in acute type B aortic dissection
- Authors:
- Roseland, Molly E
Ahmed, Yunus
van Herwaarden, Joost A
Moll, Frans L
Yang, Bo
Patel, Himanshu J
Burris, Nicholas S - Abstract:
- Abstract: : OBJECTIVES: Differential luminal enhancement [between true lumen (TL) and false lumen (FL)] results from differential flow patterns, most likely due to outflow restriction in the FL. We aimed to assess the impact of differential luminal enhancement at baseline computed tomography angiography on the risk of adverse events in patients with acute type B aortic dissection (TBAD). METHODS: Baseline computed tomography angiographies of patients with acute TBAD between 2007 and 2016 ( n = 48) were analysed using three-dimensional software at multiple sites along the descending thoraco-abdominal aorta. At each location, we measured contrast density in TL and FL [Houndsfield unit (HU)], maximal diameter (cm) and circumferential FL extent (°). Outcome data were collected via retrospective chart review. Multivariable logistic regression models were employed to determine the independent risk of TL–FL differential luminal enhancement on aneurysm formation (maximal diameter ≥55 mm) and medical treatment failure. RESULTS: Patients were predominately male (75%) and 52.8±12.9 years at diagnosis. The mean follow-up was 5.9±2.6 years, and 42% ( n = 20/48) patients were diagnosed with thoraco-abdominal aortic aneurysm. The baseline absolute difference between FL and TL contrast density measured at 2 cm distal to primary entry tear (TL–FLabs-Tear ) was significantly higher among patients who developed aneurysm (26 HU, IQR: 15–53 vs 13 HU, IQR: 4–24, P = 0.001). AneurysmAbstract: : OBJECTIVES: Differential luminal enhancement [between true lumen (TL) and false lumen (FL)] results from differential flow patterns, most likely due to outflow restriction in the FL. We aimed to assess the impact of differential luminal enhancement at baseline computed tomography angiography on the risk of adverse events in patients with acute type B aortic dissection (TBAD). METHODS: Baseline computed tomography angiographies of patients with acute TBAD between 2007 and 2016 ( n = 48) were analysed using three-dimensional software at multiple sites along the descending thoraco-abdominal aorta. At each location, we measured contrast density in TL and FL [Houndsfield unit (HU)], maximal diameter (cm) and circumferential FL extent (°). Outcome data were collected via retrospective chart review. Multivariable logistic regression models were employed to determine the independent risk of TL–FL differential luminal enhancement on aneurysm formation (maximal diameter ≥55 mm) and medical treatment failure. RESULTS: Patients were predominately male (75%) and 52.8±12.9 years at diagnosis. The mean follow-up was 5.9±2.6 years, and 42% ( n = 20/48) patients were diagnosed with thoraco-abdominal aortic aneurysm. The baseline absolute difference between FL and TL contrast density measured at 2 cm distal to primary entry tear (TL–FLabs-Tear ) was significantly higher among patients who developed aneurysm (26 HU, IQR: 15–53 vs 13 HU, IQR: 4–24, P = 0.001). Aneurysm development during follow-up was predicted by TL–FLabs-Tear (odds ratio 1.07, P = 0.012) and baseline maximal aortic diameter (odds ratio 1.90, P < 0.001). High (≥18 HU) differential luminal enhancement was associated with lower rates of aneurysm-free survival and higher rates of medical treatment failure. CONCLUSIONS: Differential luminal enhancement may be a novel predictor of aneurysm formation among patients with acute TBAD. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 33:Number 3(2021)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 33:Number 3(2021)
- Issue Display:
- Volume 33, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 3
- Issue Sort Value:
- 2021-0033-0003-0000
- Page Start:
- 434
- Page End:
- 441
- Publication Date:
- 2021-05-08
- Subjects:
- False lumen differential enhancement -- Acute type B aortic dissection -- CTA -- Aneurysm formation
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivab095 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25823.xml