External fixation of airway stents for upper tracheal stenosis and tracheoesophageal fistula. (20th April 2021)
- Record Type:
- Journal Article
- Title:
- External fixation of airway stents for upper tracheal stenosis and tracheoesophageal fistula. (20th April 2021)
- Main Title:
- External fixation of airway stents for upper tracheal stenosis and tracheoesophageal fistula
- Authors:
- Niwa, Hideyuki
Oki, Masahide
Saka, Hideo
Torii, Atsushi
Yamada, Arisa
Shigematsu, Fumie
Ishida, Akane
Kogure, Yoshihito - Abstract:
- Abstract: : OBJECTIVES: Stent migration is a common complication of airway stent placement for upper tracheal stenosis and tracheoesophageal fistula. Although several researchers have reported that external fixation is effective in preventing stent migration, the usefulness and safety of external fixation have not been proved because their cohorts were small. We therefore investigated the efficacy and safety of external fixation during upper tracheal stenting. METHODS: Records of patients who underwent airway stent placement from May 2007 to August 2018 in a single centre were retrospectively reviewed. We included only patients whose stent had been placed in the upper trachea with external fixation to the tracheal wall. The primary endpoint of this study was the rate of stent migration. RESULTS: Altogether, 51 procedures were performed in 45 patients (32 males, 13 females; median age 60 years, range 14–91 years). The median follow-up period was 9 months (range 0.3–90 months). Among the procedures, 15 were performed for benign disease and 36 for malignancy. Stents were composed of either silicone ( n = 42) or metal ( n = 9). Stent migration occurred in 3 (6%) patients. The stents with migration were all composed of silicone. Other sequelae were granulation tissue formation in 10 (20%) patients, sputum obstruction in 6 (12%), cellulitis in 3 (6%) and pneumonia in 1 (2%). CONCLUSIONS: External fixation was an effective method for preventing migration of airway stents placedAbstract: : OBJECTIVES: Stent migration is a common complication of airway stent placement for upper tracheal stenosis and tracheoesophageal fistula. Although several researchers have reported that external fixation is effective in preventing stent migration, the usefulness and safety of external fixation have not been proved because their cohorts were small. We therefore investigated the efficacy and safety of external fixation during upper tracheal stenting. METHODS: Records of patients who underwent airway stent placement from May 2007 to August 2018 in a single centre were retrospectively reviewed. We included only patients whose stent had been placed in the upper trachea with external fixation to the tracheal wall. The primary endpoint of this study was the rate of stent migration. RESULTS: Altogether, 51 procedures were performed in 45 patients (32 males, 13 females; median age 60 years, range 14–91 years). The median follow-up period was 9 months (range 0.3–90 months). Among the procedures, 15 were performed for benign disease and 36 for malignancy. Stents were composed of either silicone ( n = 42) or metal ( n = 9). Stent migration occurred in 3 (6%) patients. The stents with migration were all composed of silicone. Other sequelae were granulation tissue formation in 10 (20%) patients, sputum obstruction in 6 (12%), cellulitis in 3 (6%) and pneumonia in 1 (2%). CONCLUSIONS: External fixation was an effective method for preventing migration of airway stents placed for upper tracheal stenosis and tracheoesophageal fistula. The complications were acceptable in terms of safety. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 33:Number 3(2021)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 33:Number 3(2021)
- Issue Display:
- Volume 33, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 3
- Issue Sort Value:
- 2021-0033-0003-0000
- Page Start:
- 442
- Page End:
- 447
- Publication Date:
- 2021-04-20
- Subjects:
- Airway stent -- External fixation -- Stent migration -- Tracheal stenosis -- Tracheoesophageal fistula
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivab098 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25823.xml