X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: a preliminary study. (28th February 2021)
- Record Type:
- Journal Article
- Title:
- X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: a preliminary study. (28th February 2021)
- Main Title:
- X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: a preliminary study
- Authors:
- Guillot, Marc-Samir
Rouchaud, Aymeric
Mounayer, Charbel
Tricard, Jérémy
Belgacem, Alexis
Auditeau, Emilie
Omraam, Olivier
Fourcade, Laurent
Ballouhey, Quentin - Abstract:
- Abstract: : OBJECTIVES: To compare a standard protocol using chest computed tomography (CT) to a non-irradiant protocol involving a low-cost portable 3D scanner and magnetic resonance imaging (MRI) for all pectus deformities based on the Haller index (HI). METHODS: From April 2019 to March 2020, all children treated for pectus excavatum or carinatum at our institution were evaluated by chest CT, 3D scanning (iPad with Structure Sensor and Captevia—Rodin4D) and MRI. The main objectives were to compare the HI determined by CT or MRI to a derived index evaluated with 3D scanning, the external Haller index (EHI). The secondary objectives were to assess the inter-rater variability and the concordance between CT and MRI for the HI and the correction index. RESULTS: Eleven patients were evaluated. We identified a strong correlation between the HI with MRI and the EHI (Pearson correlation coefficient = 0.900; P < 0.001), with a strong concordance between a radiologist and a non-radiologist using intra-class correlation for the HI with MRI (intra-class correlation coefficient = 0.995; [0.983; 0.999]) and the EHI (intra-class correlation coefficient = 0.978; [0.823; 0.995]). We also identified a marked correlation between the HI with CT and the EHI (Pearson coefficient = 0.855; P = 0.002), with a strong inter-rater concordance (intra-class correlation coefficient = 0.975; [0.901; 0.993]), a reliable concordance between CT and MRI for the HI and the correction index (PearsonAbstract: : OBJECTIVES: To compare a standard protocol using chest computed tomography (CT) to a non-irradiant protocol involving a low-cost portable 3D scanner and magnetic resonance imaging (MRI) for all pectus deformities based on the Haller index (HI). METHODS: From April 2019 to March 2020, all children treated for pectus excavatum or carinatum at our institution were evaluated by chest CT, 3D scanning (iPad with Structure Sensor and Captevia—Rodin4D) and MRI. The main objectives were to compare the HI determined by CT or MRI to a derived index evaluated with 3D scanning, the external Haller index (EHI). The secondary objectives were to assess the inter-rater variability and the concordance between CT and MRI for the HI and the correction index. RESULTS: Eleven patients were evaluated. We identified a strong correlation between the HI with MRI and the EHI (Pearson correlation coefficient = 0.900; P < 0.001), with a strong concordance between a radiologist and a non-radiologist using intra-class correlation for the HI with MRI (intra-class correlation coefficient = 0.995; [0.983; 0.999]) and the EHI (intra-class correlation coefficient = 0.978; [0.823; 0.995]). We also identified a marked correlation between the HI with CT and the EHI (Pearson coefficient = 0.855; P = 0.002), with a strong inter-rater concordance (intra-class correlation coefficient = 0.975; [0.901; 0.993]), a reliable concordance between CT and MRI for the HI and the correction index (Pearson coefficient = 0.886; P = 0.033). CONCLUSIONS: Non-irradiant pectus deformity assessment is possible in clinical practice, replacing CT with MRI and 3D scanning as a possible readily-accessible monitoring tool. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 33:Number 1(2021)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 33:Number 1(2021)
- Issue Display:
- Volume 33, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2021-0033-0001-0000
- Page Start:
- 110
- Page End:
- 118
- Publication Date:
- 2021-02-28
- Subjects:
- Non-irradiant imaging -- Pectus excavatum -- Pectus carinatum -- Fast Magnetic Resonance Imaging -- 3D scanning -- Haller index
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivab036 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25827.xml