Comparison of 100-Kilovoltage Tin Filtration With Advanced Modeled Iterative Reconstruction Protocol to an Automated Kilovoltage Selection With Filtered Back Projection Protocol on Radiation Dose and Image Quality in Pediatric Noncontrast-Enhanced Chest Computed Tomography. Issue 1 (January 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of 100-Kilovoltage Tin Filtration With Advanced Modeled Iterative Reconstruction Protocol to an Automated Kilovoltage Selection With Filtered Back Projection Protocol on Radiation Dose and Image Quality in Pediatric Noncontrast-Enhanced Chest Computed Tomography. Issue 1 (January 2022)
- Main Title:
- Comparison of 100-Kilovoltage Tin Filtration With Advanced Modeled Iterative Reconstruction Protocol to an Automated Kilovoltage Selection With Filtered Back Projection Protocol on Radiation Dose and Image Quality in Pediatric Noncontrast-Enhanced Chest Computed Tomography
- Authors:
- Siegel, Marilyn J.
Raptis, Demetrios
Bhalla, Sanjeev
Ramirez-Giraldo, Juan Carlos - Abstract:
- Abstract : Objective: The aim of the study was to compare effects of a 100-kilovoltage (kVp) tin filtration (Sn100kVp) with Advanced Modeled Iterative Reconstruction (ADMIRE) protocol to an automated kVp selection and filtered back projection (FBP) protocol on radiation dose and image quality of in noncontrast-enhanced pediatric chest computed tomography (CT). Methods: This retrospective study included 55 children (12 ± 6 years) undergoing baseline imaging using automated kVp selection with FBP on a second-generation dual-source CT scanner and follow-up CT using Sn100kVp with ADMIRE on a third-generation dual-source CT scanner. The volume CT dose index, dose length product, size-specific dose estimate, and milliamperage were compared. Image quality was calculated using signal-to-noise ratio and subjectively evaluated by 2 radiologists. Results: Mean volume CT dose index, dose length product, and size-specific dose estimate were lower for the Sn100kVp protocol with ADMIRE (0.83 ± 0.18 mGy, 21.9 ± 7.5 mGy × cm, 1.28 ± 0.24 mGy) compared with the automated kVp protocol with FBP (2.17 ± 1.10 mGy, 65.1 ± 41.1 mGy × cm, 3.25 ± 1.44 mGy, P < 0.001), whereas milliamperage was and subjective image quality were higher for Sn100kVp ( P < 0.001). Conclusions: A Sn100kVp protocol with ADMIRE lowers dose while maintaining image quality in noncontrast-enhanced pediatric chest CT.
- Is Part Of:
- Journal of computer assisted tomography. Volume 46:Issue 1(2022)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 46:Issue 1(2022)
- Issue Display:
- Volume 46, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 46
- Issue:
- 1
- Issue Sort Value:
- 2022-0046-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01
- Subjects:
- computed tomography -- radiation dose -- pediatrics -- lung transplantation -- dual-source CT
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000001248 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25808.xml