Feasibility of Adjacent Insulin Infusion and Continuous Glucose Monitoring via the Medtronic Combo-Set. (March 2013)
- Record Type:
- Journal Article
- Title:
- Feasibility of Adjacent Insulin Infusion and Continuous Glucose Monitoring via the Medtronic Combo-Set. (March 2013)
- Main Title:
- Feasibility of Adjacent Insulin Infusion and Continuous Glucose Monitoring via the Medtronic Combo-Set
- Authors:
- O'Neal, David N.
Adhya, Sumona
Jenkins, Alicia
Ward, Glenn
Welsh, John B.
Voskanyan, Gayane - Abstract:
- Background: Subcutaneously infused insulin may interfere with the function of nearby glucose-sensing electrodes and vice versa . The prototype of the Combo-Set device (Medtronic) incorporates a subcutaneous insulin delivery catheter and continuous glucose monitoring (CGM) sensor assembled on the same platform and separated by 11 mm. We aim to evaluate Combo-Set's insulin delivery and glucose-sensing functions. Methods: Ten subjects with type 1 diabetes wore a Combo-Set and a Sof-Sensor inserted subcutaneously in contralateral abdominal areas connected to i Pro recorders (Medtronic) for 53.25 ± 0.75 h (mean ± standard deviation). The Combo-Set delivered insulin diluent except during meal tests on days 1 and 3 when insulin lispro was delivered as a meal bolus and postmeal basal. Venous plasma samples were collected at the following time points from meal start: 0, 30, 60, 120, and 180 min for insulin measurements. The accuracy of the Combo-Set sensors was evaluated and compared with that of the Sof-Sensor, with each referenced against capillary glucose values (Contour Link Meter, Bayer). Results: Accuracy of the Combo-Set sensor was comparable to that of the Sof-Sensor. Clarke error grid analysis showed that 97% of Combo-Set and 93% of Sof-Sensor values were in the A+B regions ( p = .20, not significant). The Combo-Set showed the expected postbolus peak insulin time (67 ± 9 min, mean ± standard error). One "no delivery" alarm occurred during the 21 patient days of use.Background: Subcutaneously infused insulin may interfere with the function of nearby glucose-sensing electrodes and vice versa . The prototype of the Combo-Set device (Medtronic) incorporates a subcutaneous insulin delivery catheter and continuous glucose monitoring (CGM) sensor assembled on the same platform and separated by 11 mm. We aim to evaluate Combo-Set's insulin delivery and glucose-sensing functions. Methods: Ten subjects with type 1 diabetes wore a Combo-Set and a Sof-Sensor inserted subcutaneously in contralateral abdominal areas connected to i Pro recorders (Medtronic) for 53.25 ± 0.75 h (mean ± standard deviation). The Combo-Set delivered insulin diluent except during meal tests on days 1 and 3 when insulin lispro was delivered as a meal bolus and postmeal basal. Venous plasma samples were collected at the following time points from meal start: 0, 30, 60, 120, and 180 min for insulin measurements. The accuracy of the Combo-Set sensors was evaluated and compared with that of the Sof-Sensor, with each referenced against capillary glucose values (Contour Link Meter, Bayer). Results: Accuracy of the Combo-Set sensor was comparable to that of the Sof-Sensor. Clarke error grid analysis showed that 97% of Combo-Set and 93% of Sof-Sensor values were in the A+B regions ( p = .20, not significant). The Combo-Set showed the expected postbolus peak insulin time (67 ± 9 min, mean ± standard error). One "no delivery" alarm occurred during the 21 patient days of use. Conclusion: A device providing for simultaneous adjacent placement of an insulin infusion catheter and a CGM sensor is feasible and functions within acceptable limits. The low "no delivery" alarm rate was similar to that of other infusion sets. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 7:Number 2(2013)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 7:Number 2(2013)
- Issue Display:
- Volume 7, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 7
- Issue:
- 2
- Issue Sort Value:
- 2013-0007-0002-0000
- Page Start:
- 381
- Page End:
- 388
- Publication Date:
- 2013-03
- Subjects:
- accuracy -- colocalization -- continuous glucose monitoring -- glucose sensing -- insulin delivery
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/193229681300700214 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25839.xml