A Single-Center Experience With Total Percutaneous Implantation of a Low-Profile Thoracic Aortic Stent-Graft. (April 2023)
- Record Type:
- Journal Article
- Title:
- A Single-Center Experience With Total Percutaneous Implantation of a Low-Profile Thoracic Aortic Stent-Graft. (April 2023)
- Main Title:
- A Single-Center Experience With Total Percutaneous Implantation of a Low-Profile Thoracic Aortic Stent-Graft
- Authors:
- Benfor, Bright
Stana, Jan
Fernandez Prendes, Carlota
Pichlmaier, Maximilian
Mehmedovic, Aldin
Banafsche, Ramin
Rantner, Barbara
Tsilimparis, Nikolaos - Abstract:
- Purpose: To evaluate the safety and effectiveness of total percutaneous implantation of the Zenith Alpha Thoracic (ZTA) endograft in the treatment of diseases of the descending thoracic aorta. Materials and Methods: A retrospective cohort study of 56 consecutive patients undergoing total percutaneous ZTA implantation between 2018 and 2020 was performed in a single center. Patients' demographics, clinical characteristics, anatomical parameters, operative details, device features, and postoperative outcomes were assessed. The primary endpoint was ongoing clinical success. A Cox regression model was used to determine the predictive factors of worse postoperative outcomes. Results: Eighty-three ZTA endografts were implanted in 35 men and 21 women with a mean age of 69±11 years for the treatment of 26 degenerative aneurysms, 15 type B dissections, and 8 penetrating ulcers, among others. Primary technical success was 100%, with a 30-day ongoing clinical success rate of 94.6%. The 1-year ongoing clinical success rate was 91.1% (51 patients), and freedoms from all-cause mortality, type 1 and 3 endoleaks, and any unplanned reintervention were, respectively, 95.3%, 91.4%, and 88.2% at 1 year. During follow-up, there was one case of surgical conversion for an aorto-esophageal fistula. On the contrary, neither aneurysmal rupture nor significant aneurysmal expansion was recorded. Repair of ruptured thoracic aorta and a high ratio of sheath outer diameter to external iliac artery diameterPurpose: To evaluate the safety and effectiveness of total percutaneous implantation of the Zenith Alpha Thoracic (ZTA) endograft in the treatment of diseases of the descending thoracic aorta. Materials and Methods: A retrospective cohort study of 56 consecutive patients undergoing total percutaneous ZTA implantation between 2018 and 2020 was performed in a single center. Patients' demographics, clinical characteristics, anatomical parameters, operative details, device features, and postoperative outcomes were assessed. The primary endpoint was ongoing clinical success. A Cox regression model was used to determine the predictive factors of worse postoperative outcomes. Results: Eighty-three ZTA endografts were implanted in 35 men and 21 women with a mean age of 69±11 years for the treatment of 26 degenerative aneurysms, 15 type B dissections, and 8 penetrating ulcers, among others. Primary technical success was 100%, with a 30-day ongoing clinical success rate of 94.6%. The 1-year ongoing clinical success rate was 91.1% (51 patients), and freedoms from all-cause mortality, type 1 and 3 endoleaks, and any unplanned reintervention were, respectively, 95.3%, 91.4%, and 88.2% at 1 year. During follow-up, there was one case of surgical conversion for an aorto-esophageal fistula. On the contrary, neither aneurysmal rupture nor significant aneurysmal expansion was recorded. Repair of ruptured thoracic aorta and a high ratio of sheath outer diameter to external iliac artery diameter were found to be independently associated with worse outcomes, with adjusted odds ratios of 4.4 [1.5-15.3] and 4.9 [1.1-23.9], respectively. Conclusion: The outcomes of total percutaneous implantation of ZTA endograft show excellent primary technical success and favorable midterm ongoing clinical success. Factors associated with worse outcomes include the repair of ruptured aorta and a high sheath to access vessel ratio. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 30:Number 2(2023)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 30:Number 2(2023)
- Issue Display:
- Volume 30, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 30
- Issue:
- 2
- Issue Sort Value:
- 2023-0030-0002-0000
- Page Start:
- 214
- Page End:
- 222
- Publication Date:
- 2023-04
- Subjects:
- TEVAR -- thoracic aneurysm -- type B dissection -- penetrating aortic ulcer -- endovascular repair -- thoracic endograft -- low profile -- aortic stent-graft
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/15266028221079767 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25813.xml