Design Characteristics of a Three-Dimensional Geometric Aortic Valve Annuloplasty Ring. Issue 5 (June 2013)
- Record Type:
- Journal Article
- Title:
- Design Characteristics of a Three-Dimensional Geometric Aortic Valve Annuloplasty Ring. Issue 5 (June 2013)
- Main Title:
- Design Characteristics of a Three-Dimensional Geometric Aortic Valve Annuloplasty Ring
- Authors:
- Crooke, Philip S.
Beavan, L. Alan
Griffin, Charles D.
Mazzitelli, Domenico
Rankin, J. Scott - Abstract:
- Objective: A full geometric annuloplasty ring could facilitate aortic valve repair. The purpose of this report was to document the design of such a ring using mathematical analyses of normal human aortic valve computed tomographic angiograms. Methods: One-millimeter axial slices of high-resolution computed tomographic angiograms from 11 normal aortic roots were used to generate high-density x, y, and z coordinates of valve structures in Mathematica. Three-dimensional least squares regression analyses of leaflet-sinus coordinates were used to assess geometry of aortic valve and root structures. Results: Normal valve geometry could be represented as three leaflet-sinus general ellipsoids nested within an elliptical aortic root. Minor-major diameter ratio of the valve base was 0.60 ± 0.07, and elliptical geometry extended vertically up the commissures. By contrast, leaflet-sinus horizontal circumferences were fairly circular (diameter ratios, 0.82–0.87), and the left coronary/noncoronary commissural post was located at the posterior base minor diameter-circumference junction, with the center of the right coronary leaflet opposite. Post location on the circumference was symmetrical, with a deviation of only ±2% to ±3% from 33.3% symmetry. Commissural posts flared outward by 5 to 10 degrees, and leaflet areas were statistically equivalent ( P > 0.10). From end diastole to midsystole, the aortic root became less elliptical (diameter ratio increased by 0.15), but root area expandedObjective: A full geometric annuloplasty ring could facilitate aortic valve repair. The purpose of this report was to document the design of such a ring using mathematical analyses of normal human aortic valve computed tomographic angiograms. Methods: One-millimeter axial slices of high-resolution computed tomographic angiograms from 11 normal aortic roots were used to generate high-density x, y, and z coordinates of valve structures in Mathematica. Three-dimensional least squares regression analyses of leaflet-sinus coordinates were used to assess geometry of aortic valve and root structures. Results: Normal valve geometry could be represented as three leaflet-sinus general ellipsoids nested within an elliptical aortic root. Minor-major diameter ratio of the valve base was 0.60 ± 0.07, and elliptical geometry extended vertically up the commissures. By contrast, leaflet-sinus horizontal circumferences were fairly circular (diameter ratios, 0.82–0.87), and the left coronary/noncoronary commissural post was located at the posterior base minor diameter-circumference junction, with the center of the right coronary leaflet opposite. Post location on the circumference was symmetrical, with a deviation of only ±2% to ±3% from 33.3% symmetry. Commissural posts flared outward by 5 to 10 degrees, and leaflet areas were statistically equivalent ( P > 0.10). From end diastole to midsystole, the aortic root became less elliptical (diameter ratio increased by 0.15), but root area expanded minimally (less than +5%). A one-piece rigid annuloplasty ring was designed with 2:3 base ellipticality, three 10-degree outwardly flaring symmetrical posts, and post height = base circumference/2π. Conclusions: A three-dimensional aortic annuloplasty ring was designed that could prove useful for enhancing applicability and stability of aortic valve repair. … (more)
- Is Part Of:
- Innovations. Volume 8:Issue 5(2013)
- Journal:
- Innovations
- Issue:
- Volume 8:Issue 5(2013)
- Issue Display:
- Volume 8, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 8
- Issue:
- 5
- Issue Sort Value:
- 2013-0008-0005-0000
- Page Start:
- 364
- Page End:
- 370
- Publication Date:
- 2013-06
- Subjects:
- Aortic valve repair -- Aortic valve geometry -- Annuloplasty
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/imi.0000000000000026 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25807.xml