An Automated Algorithm for Optic Nerve Sheath Diameter Assessment from B‐mode Ultrasound Images. Issue 4 (30th March 2021)
- Record Type:
- Journal Article
- Title:
- An Automated Algorithm for Optic Nerve Sheath Diameter Assessment from B‐mode Ultrasound Images. Issue 4 (30th March 2021)
- Main Title:
- An Automated Algorithm for Optic Nerve Sheath Diameter Assessment from B‐mode Ultrasound Images
- Authors:
- Stevens, Raoul R. F.
Huberts, Wouter
Gommer, Erik D.
Ertl, Michael
Aries, Marcel
Mess, Werner H.
Delhaas, Tammo - Abstract:
- ABSTRACT: BACKGROUND AND PURPOSE: The optic nerve sheath diameter (ONSD) is a promising surrogate marker for the detection of raised intracranial pressure (ICP). However, inconsistencies in manual ONSD assessment are thought to affect ONSD and the corresponding ONSD cutoff values for the diagnosis of elevated ICP, hereby hampering the full potential of ONSD. In this study, we developed an image intensity‐invariant algorithm to automatically estimate ONSD from B‐mode ultrasound images at multiple depths. METHODS: The outcomes of the algorithm were validated against manual ONSD measurements by two human experts. Each expert analyzed the images twice (M1 and M2) in unknown order. RESULTS: The algorithm proved capable of segmenting the ONSD in 39 of 42 images, hereby showing mean differences of −.08 ± .45 and −.05 ± .41 mm compared to averaged ONSD values (M1 + M2/2) of Operator 1 and Operator 2, respectively, whereas the mean difference between the two experts was .03 ± .26 mm. Moreover, differences between algorithm‐derived and expert‐derived ONSD values were found to be much smaller than the 1 mm difference that is expected between patients with normal and elevated ICP, making it likely that our algorithm can distinguish between these patient groups. CONCLUSIONS: Our algorithm has the potential to improve the accuracy of ONSD as a surrogate marker for elevated ICP because it has no intrinsic variability. However, future research should be performed to validate if theABSTRACT: BACKGROUND AND PURPOSE: The optic nerve sheath diameter (ONSD) is a promising surrogate marker for the detection of raised intracranial pressure (ICP). However, inconsistencies in manual ONSD assessment are thought to affect ONSD and the corresponding ONSD cutoff values for the diagnosis of elevated ICP, hereby hampering the full potential of ONSD. In this study, we developed an image intensity‐invariant algorithm to automatically estimate ONSD from B‐mode ultrasound images at multiple depths. METHODS: The outcomes of the algorithm were validated against manual ONSD measurements by two human experts. Each expert analyzed the images twice (M1 and M2) in unknown order. RESULTS: The algorithm proved capable of segmenting the ONSD in 39 of 42 images, hereby showing mean differences of −.08 ± .45 and −.05 ± .41 mm compared to averaged ONSD values (M1 + M2/2) of Operator 1 and Operator 2, respectively, whereas the mean difference between the two experts was .03 ± .26 mm. Moreover, differences between algorithm‐derived and expert‐derived ONSD values were found to be much smaller than the 1 mm difference that is expected between patients with normal and elevated ICP, making it likely that our algorithm can distinguish between these patient groups. CONCLUSIONS: Our algorithm has the potential to improve the accuracy of ONSD as a surrogate marker for elevated ICP because it has no intrinsic variability. However, future research should be performed to validate if the algorithm does indeed result in more accurate noninvasive ICP predictions. … (more)
- Is Part Of:
- Journal of neuroimaging. Volume 31:Issue 4(2021)
- Journal:
- Journal of neuroimaging
- Issue:
- Volume 31:Issue 4(2021)
- Issue Display:
- Volume 31, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 31
- Issue:
- 4
- Issue Sort Value:
- 2021-0031-0004-0000
- Page Start:
- 724
- Page End:
- 732
- Publication Date:
- 2021-03-30
- Subjects:
- Algorithm -- intracranial pressure -- ONSD -- ultrasound
Diagnostic imaging -- Periodicals
Nervous system -- Diseases -- Diagnosis -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Système nerveux -- Maladies -- Diagnostic -- Périodiques
Imagerie médicale
Neuroimagerie
Neurologie
Système nerveux
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.804754 - Journal URLs:
- http://jon.sagepub.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1552-6569 ↗
http://www.ingentaconnect.com/content/bpl/jon ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jon.12851 ↗
- Languages:
- English
- ISSNs:
- 1051-2284
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5021.548000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25785.xml