Pipeline Embolization Devices for the Treatment of Intracranial Aneurysms, Single-Center Registry: Long-Term Angiographic and Clinical Outcomes from 1000 Aneurysms. Issue 3 (7th June 2021)
- Record Type:
- Journal Article
- Title:
- Pipeline Embolization Devices for the Treatment of Intracranial Aneurysms, Single-Center Registry: Long-Term Angiographic and Clinical Outcomes from 1000 Aneurysms. Issue 3 (7th June 2021)
- Main Title:
- Pipeline Embolization Devices for the Treatment of Intracranial Aneurysms, Single-Center Registry: Long-Term Angiographic and Clinical Outcomes from 1000 Aneurysms
- Authors:
- Lylyk, Ivan
Scrivano, Esteban
Lundquist, Javier
Ferrario, Angel
Bleise, Carlos
Perez, Nicolas
Lylyk, Pedro Nicolas
Viso, Rene
Nella-Castro, Rodolfo
Lylyk, Pedro - Abstract:
- Abstract: BACKGROUND: Prospective studies have established the safety and efficacy of the Pipeline TM Embolization Device (PED; Medtronic) for treatment of intracranial aneurysms (IA). OBJECTIVE: To investigate long-term outcomes from the Pipeline Embolization Devices for the Treatment of Intracranial Aneurysms (PEDESTRIAN) Registry. METHODS: The PEDESTRIAN Registry data were retrospectively reviewed, which included patients (March 2006 to July 2019) with complex IAs treated with PED. Patients with unfavorable anatomy and/or recurrence following previous treatment were included and excluded those with acute subarachnoid hemorrhage. The primary angiographic endpoint was complete occlusion and long-term stability. Clinical and radiological follow-up was performed at 3 to 6 mo, 12 mo, and yearly thereafter. RESULTS: A total of 835 patients (mean age 55.9 ± 14.7 yr; 80.0% female) with 1000 aneurysms were included. Aneurysms varied in size: 64.6% were small (≤10 mm), 25.6% were large (11-24 mm), and 9.8% were giant (≥25 mm). A total of 1214 PEDs were deployed. Follow-up angiography was available for 85.1% of patients with 776 aneurysms at 24.6 ± 25.0 mo (mean). Complete occlusion was demonstrated in 75.8% of aneurysms at 12 mo, 92.9% at 2 to 4 yr, and 96.4% at >5 yr. During the postprocedural period, modified Rankin Scale scores remained stable or improved in 96.2% of patients, with stability or improvement in 99.1% of patients >5 yr. The overall major morbidity and neurologicalAbstract: BACKGROUND: Prospective studies have established the safety and efficacy of the Pipeline TM Embolization Device (PED; Medtronic) for treatment of intracranial aneurysms (IA). OBJECTIVE: To investigate long-term outcomes from the Pipeline Embolization Devices for the Treatment of Intracranial Aneurysms (PEDESTRIAN) Registry. METHODS: The PEDESTRIAN Registry data were retrospectively reviewed, which included patients (March 2006 to July 2019) with complex IAs treated with PED. Patients with unfavorable anatomy and/or recurrence following previous treatment were included and excluded those with acute subarachnoid hemorrhage. The primary angiographic endpoint was complete occlusion and long-term stability. Clinical and radiological follow-up was performed at 3 to 6 mo, 12 mo, and yearly thereafter. RESULTS: A total of 835 patients (mean age 55.9 ± 14.7 yr; 80.0% female) with 1000 aneurysms were included. Aneurysms varied in size: 64.6% were small (≤10 mm), 25.6% were large (11-24 mm), and 9.8% were giant (≥25 mm). A total of 1214 PEDs were deployed. Follow-up angiography was available for 85.1% of patients with 776 aneurysms at 24.6 ± 25.0 mo (mean). Complete occlusion was demonstrated in 75.8% of aneurysms at 12 mo, 92.9% at 2 to 4 yr, and 96.4% at >5 yr. During the postprocedural period, modified Rankin Scale scores remained stable or improved in 96.2% of patients, with stability or improvement in 99.1% of patients >5 yr. The overall major morbidity and neurological mortality rate was 5.8%. CONCLUSION: This study demonstrated high rates of long-term complete aneurysm occlusion, stable or improved functional outcomes, and low rates of complications and mortality. Clinical and angiographic outcomes improved over long-term follow-up, demonstrating that endovascular treatment of IA with PED is safe and effective. Graphical Abstract: … (more)
- Is Part Of:
- Neurosurgery. Volume 89:Issue 3(2021)
- Journal:
- Neurosurgery
- Issue:
- Volume 89:Issue 3(2021)
- Issue Display:
- Volume 89, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 89
- Issue:
- 3
- Issue Sort Value:
- 2021-0089-0003-0000
- Page Start:
- 443
- Page End:
- 449
- Publication Date:
- 2021-06-07
- Subjects:
- Flow diverter -- Follow-up studies -- Intracranial aneurysm -- Stroke -- Subarachnoid hemorrhage -- Pipeline Embolization Device
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyab183 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25793.xml