Spatial analysis of acoustic noise transfer function with a human-body phantom in a clinical MRI scanner. (March 2023)
- Record Type:
- Journal Article
- Title:
- Spatial analysis of acoustic noise transfer function with a human-body phantom in a clinical MRI scanner. (March 2023)
- Main Title:
- Spatial analysis of acoustic noise transfer function with a human-body phantom in a clinical MRI scanner
- Authors:
- Hamaguchi, Takashi
Miyati, Tosiaki
Ohno, Naoki
Matsushita, Tatsuhiko
Takata, Tadanori
Matsuura, Yukihiro
Kobayashi, Satoshi
Gabata, Toshifumi - Abstract:
- Background: The acoustic noise in magnetic resonance imaging (MRI) potentially depends on the measurement position and presence of a patient inside the scanner bore. Purpose: To analyze the spatial characteristics of the acoustic noise by using the gradient-pulse-to-acoustic-noise transfer function (GPAN-TF) with and without a human-body phantom on the examination table. Material and Methods: Acoustic noise waveforms were acquired at 80 and 110 measurement positions with and without a phantom. The GPAN-TFs µPa/(mT/m) in the coils were calculated by deconvolution. The phantom effect on the spatial distribution of the acoustic noise was assessed using the peak sound pressure levels (SPLs), mean values, peak values, and peak frequencies of the GPAN-TFs. Results: The peak SPLs in all positions for the X-, Y-, and Z-gradient coils were increased by 11.1 dB, 1.4 dB, and 6.1 dB, respectively, compared with the peak SPL of the magnetic isocenter. The maximum peak SPLs among all positions of the X-, Y-, and Z-gradient coils with the phantom were increased by 4.9 dB, 7.4 dB, and 6.9 dB, respectively, relative to those without the phantom. However, the peak SPLs decreased at some positions with the phantom placed on the table (X-gradient coil = 4.6 dB, Y-gradient coil = 5.0 dB, Z-gradient coil = 8.4 dB). The most common peak frequencies were in the range of 2000–3000 Hz. Conclusion: "Hotspot" areas with and without the phantom were associated with acoustic noise sources in the clinicalBackground: The acoustic noise in magnetic resonance imaging (MRI) potentially depends on the measurement position and presence of a patient inside the scanner bore. Purpose: To analyze the spatial characteristics of the acoustic noise by using the gradient-pulse-to-acoustic-noise transfer function (GPAN-TF) with and without a human-body phantom on the examination table. Material and Methods: Acoustic noise waveforms were acquired at 80 and 110 measurement positions with and without a phantom. The GPAN-TFs µPa/(mT/m) in the coils were calculated by deconvolution. The phantom effect on the spatial distribution of the acoustic noise was assessed using the peak sound pressure levels (SPLs), mean values, peak values, and peak frequencies of the GPAN-TFs. Results: The peak SPLs in all positions for the X-, Y-, and Z-gradient coils were increased by 11.1 dB, 1.4 dB, and 6.1 dB, respectively, compared with the peak SPL of the magnetic isocenter. The maximum peak SPLs among all positions of the X-, Y-, and Z-gradient coils with the phantom were increased by 4.9 dB, 7.4 dB, and 6.9 dB, respectively, relative to those without the phantom. However, the peak SPLs decreased at some positions with the phantom placed on the table (X-gradient coil = 4.6 dB, Y-gradient coil = 5.0 dB, Z-gradient coil = 8.4 dB). The most common peak frequencies were in the range of 2000–3000 Hz. Conclusion: "Hotspot" areas with and without the phantom were associated with acoustic noise sources in the clinical MRI scanner and were enhanced by the phantom's presence. … (more)
- Is Part Of:
- Acta radiologica. Volume 64:Number 3(2023)
- Journal:
- Acta radiologica
- Issue:
- Volume 64:Number 3(2023)
- Issue Display:
- Volume 64, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 64
- Issue:
- 3
- Issue Sort Value:
- 2023-0064-0003-0000
- Page Start:
- 1212
- Page End:
- 1221
- Publication Date:
- 2023-03
- Subjects:
- Magnetic resonance imaging -- acoustic noise -- spatial analysis -- transfer function -- phantom -- frequency analysis
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/02841851221100079 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25841.xml