Risks of feature leakage and sample size dependencies in deep feature extraction for breast mass classification. Issue 6 (12th April 2021)
- Record Type:
- Journal Article
- Title:
- Risks of feature leakage and sample size dependencies in deep feature extraction for breast mass classification. Issue 6 (12th April 2021)
- Main Title:
- Risks of feature leakage and sample size dependencies in deep feature extraction for breast mass classification
- Authors:
- Samala, Ravi K.
Chan, Heang‐Ping
Hadjiiski, Lubomir
Helvie, Mark A. - Abstract:
- Abstract : Purpose: Transfer learning is commonly used in deep learning for medical imaging to alleviate the problem of limited available data. In this work, we studied the risk of feature leakage and its dependence on sample size when using pretrained deep convolutional neural network (DCNN) as feature extractor for classification breast masses in mammography. Methods: Feature leakage occurs when the training set is used for feature selection and classifier modeling while the cost function is guided by the validation performance or informed by the test performance. The high‐dimensional feature space extracted from pretrained DCNN suffers from the curse of dimensionality; feature subsets that can provide excessively optimistic performance can be found for the validation set or test set if the latter is allowed for unlimited reuse during algorithm development. We designed a simulation study to examine feature leakage when using DCNN as feature extractor for mass classification in mammography. Four thousand five hundred and seventy‐seven unique mass lesions were partitioned by patient into three sets: 3222 for training, 508 for validation, and 847 for independent testing. Three pretrained DCNNs, AlexNet, GoogLeNet, and VGG16, were first compared using a training set in fourfold cross validation and one was selected as the feature extractor. To assess generalization errors, the independent test set was sequestered as truly unseen cases. A training set of a range of sizes fromAbstract : Purpose: Transfer learning is commonly used in deep learning for medical imaging to alleviate the problem of limited available data. In this work, we studied the risk of feature leakage and its dependence on sample size when using pretrained deep convolutional neural network (DCNN) as feature extractor for classification breast masses in mammography. Methods: Feature leakage occurs when the training set is used for feature selection and classifier modeling while the cost function is guided by the validation performance or informed by the test performance. The high‐dimensional feature space extracted from pretrained DCNN suffers from the curse of dimensionality; feature subsets that can provide excessively optimistic performance can be found for the validation set or test set if the latter is allowed for unlimited reuse during algorithm development. We designed a simulation study to examine feature leakage when using DCNN as feature extractor for mass classification in mammography. Four thousand five hundred and seventy‐seven unique mass lesions were partitioned by patient into three sets: 3222 for training, 508 for validation, and 847 for independent testing. Three pretrained DCNNs, AlexNet, GoogLeNet, and VGG16, were first compared using a training set in fourfold cross validation and one was selected as the feature extractor. To assess generalization errors, the independent test set was sequestered as truly unseen cases. A training set of a range of sizes from 10% to 75% was simulated by random drawing from the available training set in addition to 100% of the training set. Three commonly used feature classifiers, the linear discriminant, the support vector machine, and the random forest were evaluated. A sequential feature selection method was used to find feature subsets that could achieve high classification performance in terms of the area under the receiver operating characteristic curve (AUC) in the validation set. The extent of feature leakage and the impact of training set size were analyzed by comparison to the performance in the unseen test set. Results: All three classifiers showed large generalization error between the validation set and the independent sequestered test set at all sample sizes. The generalization error decreased as the sample size increased. At 100% of the sample size, one classifier achieved an AUC as high as 0.91 on the validation set while the corresponding performance on the unseen test set only reached an AUC of 0.72. Conclusions: Our results demonstrate that large generalization errors can occur in AI tools due to feature leakage. Without evaluation on unseen test cases, optimistically biased performance may be reported inadvertently, and can lead to unrealistic expectations and reduce confidence for clinical implementation. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 6(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 6(2021)
- Issue Display:
- Volume 48, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 6
- Issue Sort Value:
- 2021-0048-0006-0000
- Page Start:
- 2827
- Page End:
- 2837
- Publication Date:
- 2021-04-12
- Subjects:
- breast cancer classification -- feature leakage -- generalization error -- pretrained DCNN -- sample size
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14678 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25792.xml