Morpho-metabolic post-surgical patterns of non-infected prosthetic heart valves by [18F]FDG PET/CTA: "normality" is a possible diagnosis. (20th September 2019)
- Record Type:
- Journal Article
- Title:
- Morpho-metabolic post-surgical patterns of non-infected prosthetic heart valves by [18F]FDG PET/CTA: "normality" is a possible diagnosis. (20th September 2019)
- Main Title:
- Morpho-metabolic post-surgical patterns of non-infected prosthetic heart valves by [18F]FDG PET/CTA: "normality" is a possible diagnosis
- Authors:
- Roque, Albert
Pizzi, María N
Fernández-Hidalgo, Nuria
Permanyer, Eduard
Cuellar-Calabria, Hug
Romero-Farina, Guillermo
Ríos, Remedios
Almirante, Benito
Castell-Conesa, Joan
Escobar, Manuel
Ferreira-González, Ignacio
Tornos, Pilar
Aguadé-Bruix, Santiago - Abstract:
- Abstract: Aims: To define characteristic PET/CTA patterns of FDG uptake and anatomic changes following prosthetic heart valves (PVs) implantation over time, to help not to misdiagnose post-operative inflammation and avoid false-positive cases. Methods and results: Prospective evaluation of 37 post-operative patients without suspected infection that underwent serial cardiac PET/CTA examinations at 1, 6, and 12 months after surgery, in which metabolic features (FDG uptake distribution pattern and intensity) and anatomic changes were evaluated. Standardized uptake values (SUVs) were obtained and a new measure, the valve uptake index (VUI), (SUVmax–SUVmean)/SUVmax, was tested to homogenize SUV results. In total, 111 PET/CTA scans were performed in 37 patients (19 aortic and 18 mitral valves). FDG uptake was visually detectable in 79.3% of patients and showed a diffuse, homogeneous distribution pattern in 93%. Quantitative analysis yielded a mean maximum standardized uptake value (SUVmax) of 4.46 ± 1.50 and VUI of 0.35 ± 0.10. There were no significant differences in FDG distribution or uptake values between 1, 6, or 12 months. No abnormal anatomic changes or endocarditis lesions were detected in any patient during follow-up. Conclusions: FDG uptake, often seen in recently implanted PVs, shows a characteristic pattern of post-operative inflammation and, in the absence of associated anatomic lesions, could be considered a normal finding. These features remain stable for at leastAbstract: Aims: To define characteristic PET/CTA patterns of FDG uptake and anatomic changes following prosthetic heart valves (PVs) implantation over time, to help not to misdiagnose post-operative inflammation and avoid false-positive cases. Methods and results: Prospective evaluation of 37 post-operative patients without suspected infection that underwent serial cardiac PET/CTA examinations at 1, 6, and 12 months after surgery, in which metabolic features (FDG uptake distribution pattern and intensity) and anatomic changes were evaluated. Standardized uptake values (SUVs) were obtained and a new measure, the valve uptake index (VUI), (SUVmax–SUVmean)/SUVmax, was tested to homogenize SUV results. In total, 111 PET/CTA scans were performed in 37 patients (19 aortic and 18 mitral valves). FDG uptake was visually detectable in 79.3% of patients and showed a diffuse, homogeneous distribution pattern in 93%. Quantitative analysis yielded a mean maximum standardized uptake value (SUVmax) of 4.46 ± 1.50 and VUI of 0.35 ± 0.10. There were no significant differences in FDG distribution or uptake values between 1, 6, or 12 months. No abnormal anatomic changes or endocarditis lesions were detected in any patient during follow-up. Conclusions: FDG uptake, often seen in recently implanted PVs, shows a characteristic pattern of post-operative inflammation and, in the absence of associated anatomic lesions, could be considered a normal finding. These features remain stable for at least 1 year after surgery, so questioning the recommended 3-month safety period. A new measure, the VUI, can be useful for evaluating the FDG distribution pattern. … (more)
- Is Part Of:
- European heart journal. Volume 21:Number 1(2020)
- Journal:
- European heart journal
- Issue:
- Volume 21:Number 1(2020)
- Issue Display:
- Volume 21, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 1
- Issue Sort Value:
- 2020-0021-0001-0000
- Page Start:
- 24
- Page End:
- 33
- Publication Date:
- 2019-09-20
- Subjects:
- prosthetic heart valves -- positron emission tomography -- infective endocarditis -- nuclear imaging -- cardiac surgery
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jez222 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25751.xml