Randomized evaluation of redo ablation procedures of atrial fibrillation with focal impulse and rotor modulation-guided procedures: the REDO-FIRM study. Issue 1 (3rd September 2022)
- Record Type:
- Journal Article
- Title:
- Randomized evaluation of redo ablation procedures of atrial fibrillation with focal impulse and rotor modulation-guided procedures: the REDO-FIRM study. Issue 1 (3rd September 2022)
- Main Title:
- Randomized evaluation of redo ablation procedures of atrial fibrillation with focal impulse and rotor modulation-guided procedures: the REDO-FIRM study
- Authors:
- Spitzer, Stefan G
Miller, John M
Sommer, Philipp
Szili-Torok, Tamas
Reddy, Vivek Y
Nölker, Georg
Williams, Chris
Sarver, Anne
Wilber, David J - Abstract:
- Abstract: Aims: REDO-FIRM evaluated safety and effectiveness of conventional vs. focal impulse and rotor modulation (FIRM)-guided ablation of recurrent persistent or paroxysmal atrial fibrillation (AF) after an initial AF ablation procedure. Methods and results: This prospective, multicentre, randomized study included patients with a single prior AF ablation, but with recurrent AF and reconnected pulmonary veins (PVs). Conventional ablation generally included PV re-isolation; however, additional ablation was permitted per physician discretion. In the FIRM arm, beyond PV re-isolation, basket catheter-based FIRM mapping created dynamic animations of putative rotors, which were targeted for ablation. Between May 2016 and July 2019, 269 subjects were randomized, with 243 subjects completing 12-month follow-up. Ablation beyond re-pulmonary vein isolation, the FIRM vs. Conventional arms did not differ significantly: cavo-tricuspid isthmus –9.0% vs. 15.3%, caval vein isolation –1.5% vs. 0.8%, non-PV trigger –2.2% vs. 3.8%, other –11.9% vs. 13.0%. Single procedure 12-month freedom from AF/atrial tachycardia/atrial flutter-recurrence was 63.3% (76/120) vs. 59.0% (72/122) in the FIRM and Conventional arms ( P = 0.3503). Efficacy was similar in the paroxysmal and persistent AF subgroups ( P = 0.22 and P = 0.48). The 10-day and 12-month safety endpoints were achieved in 93.3% vs. 93.8% ( P = 0.89) and 88.4% vs. 93.4% ( P = 0.22) in the FIRM and Conventional arms, respectively.Abstract: Aims: REDO-FIRM evaluated safety and effectiveness of conventional vs. focal impulse and rotor modulation (FIRM)-guided ablation of recurrent persistent or paroxysmal atrial fibrillation (AF) after an initial AF ablation procedure. Methods and results: This prospective, multicentre, randomized study included patients with a single prior AF ablation, but with recurrent AF and reconnected pulmonary veins (PVs). Conventional ablation generally included PV re-isolation; however, additional ablation was permitted per physician discretion. In the FIRM arm, beyond PV re-isolation, basket catheter-based FIRM mapping created dynamic animations of putative rotors, which were targeted for ablation. Between May 2016 and July 2019, 269 subjects were randomized, with 243 subjects completing 12-month follow-up. Ablation beyond re-pulmonary vein isolation, the FIRM vs. Conventional arms did not differ significantly: cavo-tricuspid isthmus –9.0% vs. 15.3%, caval vein isolation –1.5% vs. 0.8%, non-PV trigger –2.2% vs. 3.8%, other –11.9% vs. 13.0%. Single procedure 12-month freedom from AF/atrial tachycardia/atrial flutter-recurrence was 63.3% (76/120) vs. 59.0% (72/122) in the FIRM and Conventional arms ( P = 0.3503). Efficacy was similar in the paroxysmal and persistent AF subgroups ( P = 0.22 and P = 0.48). The 10-day and 12-month safety endpoints were achieved in 93.3% vs. 93.8% ( P = 0.89) and 88.4% vs. 93.4% ( P = 0.22) in the FIRM and Conventional arms, respectively. Conclusions: In REDO-FIRM, as compared to standard ablation, FIRM-guided ablation did not provide additional efficacy in redo ablation procedures, but FIRM-guided ablation was equally safe. Additional studies are necessary to identify any potential population able to benefit from FIRM-guided ablation. … (more)
- Is Part Of:
- Europace. Volume 25:Issue 1(2023)
- Journal:
- Europace
- Issue:
- Volume 25:Issue 1(2023)
- Issue Display:
- Volume 25, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2023-0025-0001-0000
- Page Start:
- 74
- Page End:
- 82
- Publication Date:
- 2022-09-03
- Subjects:
- Recurrent AF -- Rotor -- Focal Impulse and Rotor Modulation
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac122 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25729.xml