Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants. (January 2023)
- Record Type:
- Journal Article
- Title:
- Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants. (January 2023)
- Main Title:
- Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants
- Authors:
- Fonseca Ulloa, Carlos A.
Seeger, Anja
Hagedorn, Frederike S.
Harz, Torben
Fölsch, Christian
Ishaque, Bernd A.
Rickert, Markus
Jahnke, Alexander - Abstract:
- Highlights: New in vivo concept and algorithm to detect stem stability via micromotions. In vitro analyses don´t show biological processes after implantation. Validation and simulation for the non-invasive in vivo calculation of micromotions. This work creates a possible minimalistic solution for further in vivo diagnostics. Abstract: Aseptic loosening is a frequent cause for revision of endoprosthesis. X-ray examinations like Radio-Stereometry-Analysis (RSA) are among the most widely used in vivo methods for its detection. Nevertheless, this method is not used routinely because of bone marker and related radiation exposure. This work aims at creating a new in vivo concept to detect implant stability measuring micromotions without x-ray and to develop a corresponding algorithm. Based on the assumption of contactless measurement, the input parameters for the algorithm are the distances of each ultrasound sensor to the object (prosthesis and bone) and its position. First, the number of parameters necessary for a precise reconstruction and measurement of micromotions between objects had to be defined. Therefore, the algorithm has been tested with simulations of these parameters. Two experimental measurements, either using contact sensors or ultrasound, were used to prove the accuracy of the algorithm. Simulations indicate a high accuracy with three distances as initial parameters for each object. Contact measurements show precise representation of micromotion, and theHighlights: New in vivo concept and algorithm to detect stem stability via micromotions. In vitro analyses don´t show biological processes after implantation. Validation and simulation for the non-invasive in vivo calculation of micromotions. This work creates a possible minimalistic solution for further in vivo diagnostics. Abstract: Aseptic loosening is a frequent cause for revision of endoprosthesis. X-ray examinations like Radio-Stereometry-Analysis (RSA) are among the most widely used in vivo methods for its detection. Nevertheless, this method is not used routinely because of bone marker and related radiation exposure. This work aims at creating a new in vivo concept to detect implant stability measuring micromotions without x-ray and to develop a corresponding algorithm. Based on the assumption of contactless measurement, the input parameters for the algorithm are the distances of each ultrasound sensor to the object (prosthesis and bone) and its position. First, the number of parameters necessary for a precise reconstruction and measurement of micromotions between objects had to be defined. Therefore, the algorithm has been tested with simulations of these parameters. Two experimental measurements, either using contact sensors or ultrasound, were used to prove the accuracy of the algorithm. Simulations indicate a high accuracy with three distances as initial parameters for each object. Contact measurements show precise representation of micromotion, and the contactless measurements show the possibility of detecting various materials with a high resolution. This work lays the foundations for non-invasive detection of micromotions between the implant-bone interface. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 111(2023)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 111(2023)
- Issue Display:
- Volume 111, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 111
- Issue:
- 2023
- Issue Sort Value:
- 2023-0111-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01
- Subjects:
- Biomechanics -- Endoprosthesis -- Primary and secondary stability -- Computational model -- Data acquisition -- Ultrasound
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2022.103932 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25737.xml