Complications in pulmonary vein isolation in the Netherlands Heart Registration differ with sex and ablation technique. Issue 2 (3rd November 2020)
- Record Type:
- Journal Article
- Title:
- Complications in pulmonary vein isolation in the Netherlands Heart Registration differ with sex and ablation technique. Issue 2 (3rd November 2020)
- Main Title:
- Complications in pulmonary vein isolation in the Netherlands Heart Registration differ with sex and ablation technique
- Authors:
- Mol, Daniel
Houterman, Saskia
Balt, Jippe C
Bhagwandien, Rohit E
Blaauw, Yuri
Delnoy, Peter-Paul H
van Driel, Vincent J
Driessen, Antoine H
Folkeringa, Richard J
Hassink, Rutger J
van Huysduynen, Bart Hooft
Luermans, Justin G
Ouss, Alexandre J
Stevenhagen, Yorick J
van Veghel, Dennis
Westra, Sjoerd W
de Jong, Jonas S
de Groot, Joris R - Abstract:
- Abstract: Aims : Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1–3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. Methods and results : The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P ≤ 0.001) and vascular complications (C-RF 1.7% vs. Ph-RF 1.2% vs. CB 1.3%, P ≤ 0.001). Ph-RF was associated with fewer bleeding complications (C-RF: 1.0% vs. Ph-RF: 0.4% vs. CB: 0.7%, P = 0.020). Phrenic nerve palsy mainly occurred in patients treated with CB (C-RF: 0.1% vs. Ph-RF: 0.2% vs. CB: 1.5%, P ≤ 0.001). In total, 18.4% of patients were referred for repeat ablation within 1 year. Female sex, age, and CHA2 DS2 -VASc were independent risk factors for cardiac tamponade and bleeding complications, with an adjusted OR for female patients of 2.97 (95% CI 1.98–4.45) and 2.02 (95% CI 1.03–4.00) respectively. Conclusion :Abstract: Aims : Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1–3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. Methods and results : The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P ≤ 0.001) and vascular complications (C-RF 1.7% vs. Ph-RF 1.2% vs. CB 1.3%, P ≤ 0.001). Ph-RF was associated with fewer bleeding complications (C-RF: 1.0% vs. Ph-RF: 0.4% vs. CB: 0.7%, P = 0.020). Phrenic nerve palsy mainly occurred in patients treated with CB (C-RF: 0.1% vs. Ph-RF: 0.2% vs. CB: 1.5%, P ≤ 0.001). In total, 18.4% of patients were referred for repeat ablation within 1 year. Female sex, age, and CHA2 DS2 -VASc were independent risk factors for cardiac tamponade and bleeding complications, with an adjusted OR for female patients of 2.97 (95% CI 1.98–4.45) and 2.02 (95% CI 1.03–4.00) respectively. Conclusion : The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications. Graphical Abstract: … (more)
- Is Part Of:
- Europace. Volume 23:Issue 2(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Issue 2(2021)
- Issue Display:
- Volume 23, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 2
- Issue Sort Value:
- 2021-0023-0002-0000
- Page Start:
- 216
- Page End:
- 225
- Publication Date:
- 2020-11-03
- Subjects:
- Atrial fibrillation -- Pulmonary vein isolation -- Conventional radiofrequency ablation -- Multielectrode phased radiofrequency ablation -- Cryoballoon
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa255 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25745.xml