Timeliness of Point-of-Care Viral Load Results Improves Human Immunodeficiency Virus Monitoring in Nigeria. (24th July 2022)
- Record Type:
- Journal Article
- Title:
- Timeliness of Point-of-Care Viral Load Results Improves Human Immunodeficiency Virus Monitoring in Nigeria. (24th July 2022)
- Main Title:
- Timeliness of Point-of-Care Viral Load Results Improves Human Immunodeficiency Virus Monitoring in Nigeria
- Authors:
- Chaplin, Beth
Agbaji, Oche
Reyes Nieva, Harry
Olatunde, Bola
Chang, Charlotte
Mitruka, Kiren
Sule, Halima
Dajel, Titus
Zee, Aaron
Ahmed, Mukhtar L
Ahmed, Isah
Okonkwo, Prosper
Rawizza, Holly
Kanki, Phyllis - Abstract:
- Abstract: Background: Human immunodeficiency virus (HIV) viral load (VL) monitoring is critical for antiretroviral therapy (ART) management. Point-of-care (POC) VL testing has been reported to be feasible and preferred over standard-of-care (SOC) testing in many low- and middle-income country settings where rapid results could improve patient outcomes. Methods: The timeliness of receipt of VL results was evaluated in an open-label, randomized, controlled trial among patients newly initiating ART. Clinical outcomes with POC VL monitoring using Cepheid Xpert vs SOC VL at Jos University Teaching Hospital and Comprehensive Health Centre Zamko in Nigeria were assessed. We determined time between specimen collection and recording of VL in patient charts, receipt of results, and ART switch for those who met virologic failure criteria. Results: Between April 2018 and October 2019, we screened 696 ART-naive individuals; 273 were randomized to POC and 268 to SOC HIV-1 VL testing. Participants in the POC arm received VL results significantly faster than those in the SOC arm (0.1 median days, interquartile range [IQR], 0.1–0.2 vs 143.1 days, IQR, 56.0–177.1, respectively; P < .0001). Participants in the POC arm with confirmed virologic failure vs those in the SOC arm were switched more rapidly to a second-line regimen (0 median days, IQR, 0–28 vs 66 days, IQR, 63–123, respectively; P = .03). Conclusions: POC VL testing resulted in significant improvement in the timeliness of VL resultAbstract: Background: Human immunodeficiency virus (HIV) viral load (VL) monitoring is critical for antiretroviral therapy (ART) management. Point-of-care (POC) VL testing has been reported to be feasible and preferred over standard-of-care (SOC) testing in many low- and middle-income country settings where rapid results could improve patient outcomes. Methods: The timeliness of receipt of VL results was evaluated in an open-label, randomized, controlled trial among patients newly initiating ART. Clinical outcomes with POC VL monitoring using Cepheid Xpert vs SOC VL at Jos University Teaching Hospital and Comprehensive Health Centre Zamko in Nigeria were assessed. We determined time between specimen collection and recording of VL in patient charts, receipt of results, and ART switch for those who met virologic failure criteria. Results: Between April 2018 and October 2019, we screened 696 ART-naive individuals; 273 were randomized to POC and 268 to SOC HIV-1 VL testing. Participants in the POC arm received VL results significantly faster than those in the SOC arm (0.1 median days, interquartile range [IQR], 0.1–0.2 vs 143.1 days, IQR, 56.0–177.1, respectively; P < .0001). Participants in the POC arm with confirmed virologic failure vs those in the SOC arm were switched more rapidly to a second-line regimen (0 median days, IQR, 0–28 vs 66 days, IQR, 63–123, respectively; P = .03). Conclusions: POC VL testing resulted in significant improvement in the timeliness of VL result receipt by patients and use for effective HIV clinical management. In patients experiencing VL failure, POC monitoring enabled prompt switching to second-line ART regimens. Clinical Trials Registration: NCT03533868. Abstract : In a randomized, controlled trial in Nigeria, patients randomized to point-of-care human immunodeficiency virus type 1 viral load testing received their test results significantly faster than those receiving standard-of-care laboratory-based testing. Patients with confirmed virologic failure were switched more rapidly to a second-line regimen. … (more)
- Is Part Of:
- Clinical infectious diseases. Volume 76:Number 3(2023)
- Journal:
- Clinical infectious diseases
- Issue:
- Volume 76:Number 3(2023)
- Issue Display:
- Volume 76, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 76
- Issue:
- 3
- Issue Sort Value:
- 2023-0076-0003-0000
- Page Start:
- e671
- Page End:
- e680
- Publication Date:
- 2022-07-24
- Subjects:
- point-of-care -- viral load -- monitoring -- HIV -- Africa
Communicable diseases -- Periodicals
616.905 - Journal URLs:
- http://cid.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗
http://www.journals.uchicago.edu/CID/journal ↗
http://www.jstor.org/journals/10584838.html ↗ - DOI:
- 10.1093/cid/ciac609 ↗
- Languages:
- English
- ISSNs:
- 1058-4838
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293860
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25748.xml