Rate and nature of complications with leadless transcatheter pacemakers compared with transvenous pacemakers: results from an Italian multicentre large population analysis. Issue 1 (29th August 2022)
- Record Type:
- Journal Article
- Title:
- Rate and nature of complications with leadless transcatheter pacemakers compared with transvenous pacemakers: results from an Italian multicentre large population analysis. Issue 1 (29th August 2022)
- Main Title:
- Rate and nature of complications with leadless transcatheter pacemakers compared with transvenous pacemakers: results from an Italian multicentre large population analysis
- Authors:
- Palmisano, Pietro
Facchin, Domenico
Ziacchi, Matteo
Nigro, Gerardo
Nicosia, Antonino
Bongiorni, Maria Grazia
Tomasi, Luca
Rossi, Andrea
De Filippo, Paolo
Sgarito, Giuseppe
Verlato, Roberto
Di Silvestro, Michele
Iacopino, Saverio - Abstract:
- Abstract: Aims: The safety and efficacy of leadless intracardiac-permanent pacemaker (L-PM) have been demonstrated in multiple clinical trials, but data on comparisons with conventional transvenous-permanent pacemaker (T-PM) collected in a consecutive, prospective fashion are limited. The aim of this analysis was to compare the rate and the nature of device-related complications between patients undergoing L-PM vs. T-PM implantation. Methods and results: Prospective, multicentre, observational project enrolling consecutive patients who underwent L-PM or T-PM implantation. The rate and nature of device-related complications were analysed and compared between the two groups. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 2669 ( n = 665 L-PM) patients were included and followed for a median of 39 months, L-PM patients were on average older and had more co-morbidities. The risk of device-related complications at 12 months was significantly lower in the L-PM group (0.5% vs. 1.9%, P = 0.009). Propensity matching yielded 442 matched pairs. In the matched cohort, L-PM patients trended toward having a lower risk of overall device-related complications ( P = 0.129), had a similar risk of early complications (≤30 days) ( P = 1.000), and had a significantly lower risk of late complications (>30 days) ( P = 0.031). All complications observed in L-PM group were early. Most (75.0%) of complications observed in T-PM group were lead- orAbstract: Aims: The safety and efficacy of leadless intracardiac-permanent pacemaker (L-PM) have been demonstrated in multiple clinical trials, but data on comparisons with conventional transvenous-permanent pacemaker (T-PM) collected in a consecutive, prospective fashion are limited. The aim of this analysis was to compare the rate and the nature of device-related complications between patients undergoing L-PM vs. T-PM implantation. Methods and results: Prospective, multicentre, observational project enrolling consecutive patients who underwent L-PM or T-PM implantation. The rate and nature of device-related complications were analysed and compared between the two groups. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 2669 ( n = 665 L-PM) patients were included and followed for a median of 39 months, L-PM patients were on average older and had more co-morbidities. The risk of device-related complications at 12 months was significantly lower in the L-PM group (0.5% vs. 1.9%, P = 0.009). Propensity matching yielded 442 matched pairs. In the matched cohort, L-PM patients trended toward having a lower risk of overall device-related complications ( P = 0.129), had a similar risk of early complications (≤30 days) ( P = 1.000), and had a significantly lower risk of late complications (>30 days) ( P = 0.031). All complications observed in L-PM group were early. Most (75.0%) of complications observed in T-PM group were lead- or pocket-related. Conclusion: In this analysis, the risk of device-related complications associated with L-PM implantation tended to be lower than that of T-PM. Specifically, the risk of early complications was similar in two types of PMs, while the risk of late complications was significantly lower for L-PM than T-PM. … (more)
- Is Part Of:
- Europace. Volume 25:Issue 1(2023)
- Journal:
- Europace
- Issue:
- Volume 25:Issue 1(2023)
- Issue Display:
- Volume 25, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2023-0025-0001-0000
- Page Start:
- 112
- Page End:
- 120
- Publication Date:
- 2022-08-29
- Subjects:
- Leadless pacemaker -- Transvenous pacemaker -- Complications -- Lead-related complications -- Pocket-related complications -- Device infection
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac112 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25729.xml