Design and CT imaging of casper, an anthropomorphic breathing thorax phantom. (1st March 2023)
- Record Type:
- Journal Article
- Title:
- Design and CT imaging of casper, an anthropomorphic breathing thorax phantom. (1st March 2023)
- Main Title:
- Design and CT imaging of casper, an anthropomorphic breathing thorax phantom
- Authors:
- Laidlaw, Josie
Earl, Nicolas
Shavdia, Nihal
Davis, Rayna
Mayer, Sarah
Karaman, Dmitri
Richtsmeier, Devon
Rodesch, Pierre-Antoine
Bazalova-Carter, Magdalena - Abstract:
- Abstract: The goal of this work was to build an anthropomorphic thorax phantom capable of breathing motion with materials mimicking human tissues in x-ray imaging applications. The thorax phantom, named Casper, was composed of resin (body), foam (lungs), glow polyactic acid (bones) and natural polyactic acid (tumours placed in the lungs). X-ray attenuation properties of all materials prior to manufacturing were evaluated by means of photon-counting computed tomography (CT) imaging on a table-top system. Breathing motion was achieved by a scotch-yoke mechanism with diaphragm motion frequencies of 10−20 rpm and displacements of 1 to 2 cm. Casper was manufactured by means of 3D printing of moulds and ribs and assembled in a complex process. The final phantom was then scanned using a clinical CT scanner to evaluate material CT numbers and the extent of tumour motion. Casper CT numbers were close to human CT numbers for soft tissue (46 HU), ribs (125 HU), lungs (−840 HU) and tumours (−45 HU). For a 2 cm diaphragm displacement the largest tumour displacement was 0.7 cm. The five tumour volumes were accurately assessed in the static CT images with a mean absolute error of 4.3%. Tumour sizes were either underestimated for smaller tumours or overestimated for larger tumours in dynamic CT images due to motion blurring with a mean absolute difference from true volumes of 10.3%. More Casper information including a motion movie and manufacturing data can be downloaded fromAbstract: The goal of this work was to build an anthropomorphic thorax phantom capable of breathing motion with materials mimicking human tissues in x-ray imaging applications. The thorax phantom, named Casper, was composed of resin (body), foam (lungs), glow polyactic acid (bones) and natural polyactic acid (tumours placed in the lungs). X-ray attenuation properties of all materials prior to manufacturing were evaluated by means of photon-counting computed tomography (CT) imaging on a table-top system. Breathing motion was achieved by a scotch-yoke mechanism with diaphragm motion frequencies of 10−20 rpm and displacements of 1 to 2 cm. Casper was manufactured by means of 3D printing of moulds and ribs and assembled in a complex process. The final phantom was then scanned using a clinical CT scanner to evaluate material CT numbers and the extent of tumour motion. Casper CT numbers were close to human CT numbers for soft tissue (46 HU), ribs (125 HU), lungs (−840 HU) and tumours (−45 HU). For a 2 cm diaphragm displacement the largest tumour displacement was 0.7 cm. The five tumour volumes were accurately assessed in the static CT images with a mean absolute error of 4.3%. Tumour sizes were either underestimated for smaller tumours or overestimated for larger tumours in dynamic CT images due to motion blurring with a mean absolute difference from true volumes of 10.3%. More Casper information including a motion movie and manufacturing data can be downloaded from http://web.uvic.ca/~bazalova/Casper/. … (more)
- Is Part Of:
- Biomedical physics & engineering express. Volume 9:Number 2(2023)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 9:Number 2(2023)
- Issue Display:
- Volume 9, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 9
- Issue:
- 2
- Issue Sort Value:
- 2023-0009-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-03-01
- Subjects:
- thorax anthropomorphic phantom -- lung respiratory motion -- tissue mimicking material -- additive manufacturing -- CT imaging -- radiotherapy
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/acb7f7 ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25710.xml