Corneal Biomechanics Losses Caused by Refractive Surgery. (1st February 2023)
- Record Type:
- Journal Article
- Title:
- Corneal Biomechanics Losses Caused by Refractive Surgery. (1st February 2023)
- Main Title:
- Corneal Biomechanics Losses Caused by Refractive Surgery
- Authors:
- Bao, FangJun
Lopes, Bernardo T.
Zheng, XiaoBo
Ji, YuXin
Wang, JunJie
Elsheikh, Ahmed - Abstract:
- Abstract: Recent advances, specifically in the understanding of the biomechanical properties of the cornea and its response to diseases and surgical interventions, have significantly improved the safety and surgical outcomes of corneal refractive surgery, whose popularity and demand continue to grow worldwide. However, iatrogenic keratectasia resulting from the deterioration in corneal biomechanics caused by surgical interventions, although rare, remains a global concern. On one hand, in vivo biomechanical evaluation, enabled by clinical imaging systems such as the ORA and the Corvis ST, has significantly improved the risk profiling of patients for iatrogenic keratectasia. That is despite the fact the biomechanical metrics provided by these systems are considered indicators of the cornea's overall stiffness rather than its intrinsic material properties. On the other hand, new surgical modalities including SMILE were introduced to offer superior biomechanical performance to LASIK, but this superiority could not be proven clinically, creating more myths than answers. The literature also includes sound evidence that tPRK provided the highest preservation of corneal biomechanics when compared to both LASIK and SMILE. The aim of this review is twofold; to discuss the importance of corneal biomechanical evaluation prior to refractive surgery, and to assess the current understanding of cornea's biomechanical deterioration caused by mainstream corneal refractive surgeries. TheAbstract: Recent advances, specifically in the understanding of the biomechanical properties of the cornea and its response to diseases and surgical interventions, have significantly improved the safety and surgical outcomes of corneal refractive surgery, whose popularity and demand continue to grow worldwide. However, iatrogenic keratectasia resulting from the deterioration in corneal biomechanics caused by surgical interventions, although rare, remains a global concern. On one hand, in vivo biomechanical evaluation, enabled by clinical imaging systems such as the ORA and the Corvis ST, has significantly improved the risk profiling of patients for iatrogenic keratectasia. That is despite the fact the biomechanical metrics provided by these systems are considered indicators of the cornea's overall stiffness rather than its intrinsic material properties. On the other hand, new surgical modalities including SMILE were introduced to offer superior biomechanical performance to LASIK, but this superiority could not be proven clinically, creating more myths than answers. The literature also includes sound evidence that tPRK provided the highest preservation of corneal biomechanics when compared to both LASIK and SMILE. The aim of this review is twofold; to discuss the importance of corneal biomechanical evaluation prior to refractive surgery, and to assess the current understanding of cornea's biomechanical deterioration caused by mainstream corneal refractive surgeries. The review has led to an observation that new imaging techniques, parameters and evaluation systems may be needed to reflect the true advantages of specific refractive techniques and when these advantages are significant enough to offer better protection against post-surgery complications. … (more)
- Is Part Of:
- Current eye research. Volume 48:Number 2(2023)
- Journal:
- Current eye research
- Issue:
- Volume 48:Number 2(2023)
- Issue Display:
- Volume 48, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 48
- Issue:
- 2
- Issue Sort Value:
- 2023-0048-0002-0000
- Page Start:
- 137
- Page End:
- 143
- Publication Date:
- 2023-02-01
- Subjects:
- Keratectasia -- corneal refractive surgery -- ORA -- Corvis ST -- in vivo corneal biomechanics
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Ophthalmology -- Periodicals
573.88 - Journal URLs:
- http://informahealthcare.com/journal/cey ↗
http://www.tandfonline.com/toc/icey20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02713683.2022.2103569 ↗
- Languages:
- English
- ISSNs:
- 0271-3683
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3496.570000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25711.xml