Liquid chromatography–quadrupole orbitrap and liquid chromatography–tandem mass spectrometry system for rapid identification and quantitation of thirty nonsteroidal anti‐inflammatory drugs and acetaminophen in illegal products. (17th January 2023)
- Record Type:
- Journal Article
- Title:
- Liquid chromatography–quadrupole orbitrap and liquid chromatography–tandem mass spectrometry system for rapid identification and quantitation of thirty nonsteroidal anti‐inflammatory drugs and acetaminophen in illegal products. (17th January 2023)
- Main Title:
- Liquid chromatography–quadrupole orbitrap and liquid chromatography–tandem mass spectrometry system for rapid identification and quantitation of thirty nonsteroidal anti‐inflammatory drugs and acetaminophen in illegal products
- Authors:
- Park, Hyoung‐Joon
Ham, Hyeon Joo
Yang, Yoon Ji
Seo, Min Kyeong
Kim, Hyung Il
Lee, Ji Hyun - Abstract:
- Abstract : Rationale: As the public interest in healthcare increases, illegal dietary supplements, foods, and drugs containing unauthorized pharmaceutical ingredients, including nonsteroidal anti‐inflammatory drugs (NSAIDs) and acetaminophen, have been identified. Excessive and unintentional consumption is toxic to the gastrointestinal tract, kidneys, and liver; therefore, these pharmaceuticals must be monitored using analytical methods. Methods: A rapid and reliable analysis system involving liquid chromatography–quadrupole orbitrap mass spectrometry (LC‐Q‐Orbitrap/MS) and liquid chromatography–tandem mass spectrometry (LC/MS/MS) was established and validated to identify and quantify 30 NSAIDs and acetaminophen. In addition, we obtained the MS 2 spectrum for each component with the proposed structure of the fragment ions. Results: The analytical method was applied to 505 samples of illicitly distributed dietary supplements, foods, and pharmaceuticals. Non‐steroidal analgesics were detected in 126 samples. Carbamazepine (42.9%) and diclofenac (30.2%) were the most detected components in the samples; other pharmaceutical adulterants were also detected in some cases. Additionally, we present the identification of an unknown component, dexamethasone (799 μg/g), using LC‐Q‐Orbitrap/MS in a sample containing the unknown component with meloxicam (15.4 mg/g). Conclusions: The developed analysis system, consisting of qualitative analysis using LC‐Q‐Orbitrap/MS and quantitativeAbstract : Rationale: As the public interest in healthcare increases, illegal dietary supplements, foods, and drugs containing unauthorized pharmaceutical ingredients, including nonsteroidal anti‐inflammatory drugs (NSAIDs) and acetaminophen, have been identified. Excessive and unintentional consumption is toxic to the gastrointestinal tract, kidneys, and liver; therefore, these pharmaceuticals must be monitored using analytical methods. Methods: A rapid and reliable analysis system involving liquid chromatography–quadrupole orbitrap mass spectrometry (LC‐Q‐Orbitrap/MS) and liquid chromatography–tandem mass spectrometry (LC/MS/MS) was established and validated to identify and quantify 30 NSAIDs and acetaminophen. In addition, we obtained the MS 2 spectrum for each component with the proposed structure of the fragment ions. Results: The analytical method was applied to 505 samples of illicitly distributed dietary supplements, foods, and pharmaceuticals. Non‐steroidal analgesics were detected in 126 samples. Carbamazepine (42.9%) and diclofenac (30.2%) were the most detected components in the samples; other pharmaceutical adulterants were also detected in some cases. Additionally, we present the identification of an unknown component, dexamethasone (799 μg/g), using LC‐Q‐Orbitrap/MS in a sample containing the unknown component with meloxicam (15.4 mg/g). Conclusions: The developed analysis system, consisting of qualitative analysis using LC‐Q‐Orbitrap/MS and quantitative analysis using LC/MS/MS, can rapidly and accurately identify and quantify NSAIDs and acetaminophen while also identifying non‐analytical components. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 37:Number 6(2023)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 37:Number 6(2023)
- Issue Display:
- Volume 37, Issue 6 (2023)
- Year:
- 2023
- Volume:
- 37
- Issue:
- 6
- Issue Sort Value:
- 2023-0037-0006-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2023-01-17
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.9462 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25686.xml