Prognostic value of intracoronary imaging-derived measures for non-infarct related vessel revascularization throughout 7 years among patients with ST-elevation myocardial infarction. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Prognostic value of intracoronary imaging-derived measures for non-infarct related vessel revascularization throughout 7 years among patients with ST-elevation myocardial infarction. (25th November 2020)
- Main Title:
- Prognostic value of intracoronary imaging-derived measures for non-infarct related vessel revascularization throughout 7 years among patients with ST-elevation myocardial infarction
- Authors:
- Ueki, Y
Karagiannis, A
Bar, S
Yamaji, K
Taniwaki, M
Roffi, M
Holmvang, L
Maldonado, R
Pedrazzini, G
Kelbaek, H
Radu, M
Windecker, S
Raber, L - Abstract:
- Abstract: Background: Underlying plaque characteristics that lead to future revascularization during long-term follow-up remain poorly understood. Purpose: We aimed to explore intracoronary imaging-derived measures as assessed by intravascular ultrasound (IVUS) and optical coherence tomography (OCT) associated with non-infarct related vessel revascularization (non-TVR) arising from imaged segments during long-term (up to 7 years) follow-up among patients with ST-elevated myocardial infarction (STEMI). Methods: A total of 94 STEMI patients enrolled into the IBIS-4 (Integrated Biomarker Imaging Study-4) study undergoing serial (baseline and 13 months) IVUS and OCT in 2 non-infarct-related coronary arteries under high-intensity statin therapy were analyzed in the present study. Patients were divided into 2 groups according to the occurrence of non-TVR within previously imaged vessel segments (non-TVR: n=14, no non-TVR: n=80). Results: Baseline characteristics including LDL level were comparable between groups. At baseline, lesions with future non-TVR were associated with greater percent atheroma volume by IVUS (55.6±5.4% vs. 49.6±6.1%, P<0.001), minimum lumen area by OCT (3.4±1.7 mm 2 vs. 6.0±3.3 mm 2, P=0.004), and a higher prevalence of fibroatheroma (60.0% vs. 20.1%, P=0.007) by OCT compared with those without. Among patients with serial imaging, lesions with non-TVR had a trend towards a less reduction of percent atheroma volume (−0.2±3.8% vs. −2.4±4.2%, P=0.083).Abstract: Background: Underlying plaque characteristics that lead to future revascularization during long-term follow-up remain poorly understood. Purpose: We aimed to explore intracoronary imaging-derived measures as assessed by intravascular ultrasound (IVUS) and optical coherence tomography (OCT) associated with non-infarct related vessel revascularization (non-TVR) arising from imaged segments during long-term (up to 7 years) follow-up among patients with ST-elevated myocardial infarction (STEMI). Methods: A total of 94 STEMI patients enrolled into the IBIS-4 (Integrated Biomarker Imaging Study-4) study undergoing serial (baseline and 13 months) IVUS and OCT in 2 non-infarct-related coronary arteries under high-intensity statin therapy were analyzed in the present study. Patients were divided into 2 groups according to the occurrence of non-TVR within previously imaged vessel segments (non-TVR: n=14, no non-TVR: n=80). Results: Baseline characteristics including LDL level were comparable between groups. At baseline, lesions with future non-TVR were associated with greater percent atheroma volume by IVUS (55.6±5.4% vs. 49.6±6.1%, P<0.001), minimum lumen area by OCT (3.4±1.7 mm 2 vs. 6.0±3.3 mm 2, P=0.004), and a higher prevalence of fibroatheroma (60.0% vs. 20.1%, P=0.007) by OCT compared with those without. Among patients with serial imaging, lesions with non-TVR had a trend towards a less reduction of percent atheroma volume (−0.2±3.8% vs. −2.4±4.2%, P=0.083). Conclusion: Greater plaque burden, smaller lumen area, and higher prevalence of OCT-detected fibroatheroma at baseline were associated with non-infarct related vessel revascularization. Lesions with non-TVR tend to have less-pronounced regression of coronary atheroma despite intensive statin therapy and achieved LDL levels. Funding Acknowledgement: Type of funding source: Public grant(s) – National budget only. Main funding source(s): Swiss National Science Foundation … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Imaging: Coronary Artery Disease
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.0315 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25704.xml