Self-navigated MRI 3D whole heart sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention: comparison to cardiac CT. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Self-navigated MRI 3D whole heart sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention: comparison to cardiac CT. (25th November 2020)
- Main Title:
- Self-navigated MRI 3D whole heart sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention: comparison to cardiac CT
- Authors:
- Holzknecht, M
Pamminger, M
Tiller, C
Kranewitter, C
Kremser, C
Reindl, M
Reinstadler, S.J
Reiter, G
Piccini, D
Klug, G
Bauer, A
Metzler, B
Mayr, A - Abstract:
- Abstract: Purpose: To evaluate image quality, inter-observer reliability and diagnostic accuracy of self-navigated noncontrast 3D whole-heart magnetic resonance angiography (MRA) for transcatheter aortic valve intervention (TAVI) evaluation in comparison to standardized contrast-enhanced computed tomography angiography (CTA). Methods: Whole-heart 1.5 T MRA was performed in 33 patients (aged 84 years [IQR 79–86], 48% male) for aortic root sizing and measurements of coronary ostia heights. A subgroup of 18 (55%) patients underwent additional CTA as gold standard for TAVI measurements. Image quality was assessed by a 4-point Likert scale, continuous MRA and CTA measurements were compared with regression and Bland-Altman analysis, valve sizing by kappa statistics. Results: Median image quality of MRA as rated by two observers according was 1.5 [IQR 1.5–2.5]. In 4 patients (12%) one coronary ostium each (right coronary artery 3, left main artery 1) was not clearly definable on MRA. Inter-observer correlation was substantial to excellent (r=0.61 to 0.92) with a bias of 19 mm 2 for annulus area (lower limit of agreement −59 mm 2, upper limit of agreement 98 mm 2 ; p=0.009). Aortic root and ostia height measurements by MRA and CTA showed substantial to excellent correlation (r=0.65 to 0.90) with no significant bias (all p≥0.333). Mean annulus area for MRA was 414±71 mm 2 and for CTA 422±80 mm 2 (r=0.9) with a bias of −8 mm 2 (lower limit of agreement −79 mm 2, upper limit ofAbstract: Purpose: To evaluate image quality, inter-observer reliability and diagnostic accuracy of self-navigated noncontrast 3D whole-heart magnetic resonance angiography (MRA) for transcatheter aortic valve intervention (TAVI) evaluation in comparison to standardized contrast-enhanced computed tomography angiography (CTA). Methods: Whole-heart 1.5 T MRA was performed in 33 patients (aged 84 years [IQR 79–86], 48% male) for aortic root sizing and measurements of coronary ostia heights. A subgroup of 18 (55%) patients underwent additional CTA as gold standard for TAVI measurements. Image quality was assessed by a 4-point Likert scale, continuous MRA and CTA measurements were compared with regression and Bland-Altman analysis, valve sizing by kappa statistics. Results: Median image quality of MRA as rated by two observers according was 1.5 [IQR 1.5–2.5]. In 4 patients (12%) one coronary ostium each (right coronary artery 3, left main artery 1) was not clearly definable on MRA. Inter-observer correlation was substantial to excellent (r=0.61 to 0.92) with a bias of 19 mm 2 for annulus area (lower limit of agreement −59 mm 2, upper limit of agreement 98 mm 2 ; p=0.009). Aortic root and ostia height measurements by MRA and CTA showed substantial to excellent correlation (r=0.65 to 0.90) with no significant bias (all p≥0.333). Mean annulus area for MRA was 414±71 mm 2 and for CTA 422±80 mm 2 (r=0.9) with a bias of −8 mm 2 (lower limit of agreement −79 mm 2, upper limit of agreement −62 mm 2 ; p=0.333). Regarding prosthetic valve sizing there was complete consistency between MRA and CTA-based decisions (κ=1). Conclusion: Self-navigated noncontrast 3D whole-heart MRA enables reliable aortic root TAVI measurements without significant difference to standardized CTA. Prosthesis sizing by MRA measurements would completely match to CTA-based choice. However, in some cases coronary ostia may be difficult to define. Funding Acknowledgement: Type of funding source: None … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Imaging: Valve Disease
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.0304 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25704.xml