Effectiveness and safety of implantable loop recorder and clinical utility of remote monitoring in patients with unexplained, recurrent, traumatic syncope. (2nd January 2023)
- Record Type:
- Journal Article
- Title:
- Effectiveness and safety of implantable loop recorder and clinical utility of remote monitoring in patients with unexplained, recurrent, traumatic syncope. (2nd January 2023)
- Main Title:
- Effectiveness and safety of implantable loop recorder and clinical utility of remote monitoring in patients with unexplained, recurrent, traumatic syncope
- Authors:
- Palmisano, Pietro
Guerra, Federico
Aspromonte, Vittorio
Dell'Era, Gabriele
Pellegrino, Pier Luigi
Laffi, Mattia
Uran, Carlo
De Bonis, Silvana
Accogli, Michele
Dello Russo, Antonio
Patti, Giuseppe
Santoro, Francesco
Torriglia, Antonella
Nigro, Gerardo
Bisignani, Antonio
Coluccia, Giovanni
Stronati, Giulia
Russo, Vincenzo
Ammendola, Ernesto - Abstract:
- ABSTRACT: Background: Implantable loop recorder (ILR) is still underutilized in clinical practice, especially in the setting of elderly patients with recurrent, traumatic, unexplained syncope. Data on the actual risk of traumatic syncopal recurrence during ILR monitoring in this specific patient setting are lacking. Research design and methods: Prospective, multicentre registry enrolling consecutive patients undergoing ILR insertion for unexplained, recurrent, traumatic syncope. In a proportion of enrolled patients, remote monitoring (RM) was used for device follow-up. The risk of traumatic and non-traumatic syncopal recurrences during ILR observation were prospectively assessed. Results: A total of 483 consecutive patients (68±14 years, 59% male) were enrolled. During a median follow-up of 18 months, a final diagnosis was reached in 270 patients (55.9%). The risk of syncopal and traumatic syncopal recurrence was of 26.5 and 9.3%, respectively. RM significantly reduced the time to diagnosis (19.7±10.3 vs. 22.1±10.8 months; p=0.015) and was associated with a significant reduction in the risk of syncope recurrence of 48% (p<0.001), and of traumatic syncope recurrence of 49% (p=0.018). Conclusions: ILR monitoring is effective and safe in patients with unexplained, recurrent, traumatic syncope. RM reduces the time to diagnosis and significantly reduces the risk of traumatic and non-traumatic syncopal relapses.
- Is Part Of:
- Expert review of medical devices. Volume 20:Number 1(2023)
- Journal:
- Expert review of medical devices
- Issue:
- Volume 20:Number 1(2023)
- Issue Display:
- Volume 20, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 20
- Issue:
- 1
- Issue Sort Value:
- 2023-0020-0001-0000
- Page Start:
- 45
- Page End:
- 54
- Publication Date:
- 2023-01-02
- Subjects:
- Implantable loop recorder -- insertable cardiac monitor -- unexplained syncope -- traumatic syncope -- remote monitoring
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/loi/erd ↗
http://www.future-drugs.com/loi/erd ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/17434440.2023.2168189 ↗
- Languages:
- English
- ISSNs:
- 1743-4440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3842.002986
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 25707.xml