Experimental Study on Gastric Labeling by Magnetic Detector Combined With Magnetic Bead. Issue 1 (19th February 2023)
- Record Type:
- Journal Article
- Title:
- Experimental Study on Gastric Labeling by Magnetic Detector Combined With Magnetic Bead. Issue 1 (19th February 2023)
- Main Title:
- Experimental Study on Gastric Labeling by Magnetic Detector Combined With Magnetic Bead
- Authors:
- Hong, Donggui
Xie, Jiao
Li, Dazhou
Jiang, Chuanshen
He, Xiaojian
Zheng, Yunping
Chen, Xinjiang
Li, Han
Huang, Jianxiao
Wang, Xiaoling
Dai, Lingshuang
Liu, Meiyan
Wang, Wen - Abstract:
- Abstract : Objective: Preoperative labeling of gastric cancer is an important means to determine the surgical margin. At present, there are many commonly used labeling methods. However, which is more accurate and has fewer complications remains to be studied. Through animal experiments, this study explored the feasibility, accuracy, and safety of a magnetic detector combined with magnetic beads for the preoperative labeling of gastric cancer. Methods: A total of 10 beagle dogs were included in the study. Each dog was randomly labeled with magnetic beads in the gastric body and antrum. After labeling, the magnetic detector was used to explore the gastric serosa surface, and the positioning titanium clip was released at the detected magnetic bead. The main monitoring index was to measure the distance between the labeled magnetic beads and the positioning titanium clamped. The secondary indexes were detection time, magnetic induction intensity, magnetic bead shedding rate, mucosal injury rate, bleeding, and leukocyte and C-reactive protein levels before and 24 hours after the operation. Results: All 10 beagle dogs completed the marking and exploration successfully. The average distance between the magnetic beads and the positioning titanium clip in 20 cases was 5.90±2.36 mm. The average detection time was 1.60±0.69 min, and the average magnetic induction intensity was 3.76±1.11 mT. No magnetic beads were found to fall off, 1 case had a mild mucosal injury, and 2 cases had aAbstract : Objective: Preoperative labeling of gastric cancer is an important means to determine the surgical margin. At present, there are many commonly used labeling methods. However, which is more accurate and has fewer complications remains to be studied. Through animal experiments, this study explored the feasibility, accuracy, and safety of a magnetic detector combined with magnetic beads for the preoperative labeling of gastric cancer. Methods: A total of 10 beagle dogs were included in the study. Each dog was randomly labeled with magnetic beads in the gastric body and antrum. After labeling, the magnetic detector was used to explore the gastric serosa surface, and the positioning titanium clip was released at the detected magnetic bead. The main monitoring index was to measure the distance between the labeled magnetic beads and the positioning titanium clamped. The secondary indexes were detection time, magnetic induction intensity, magnetic bead shedding rate, mucosal injury rate, bleeding, and leukocyte and C-reactive protein levels before and 24 hours after the operation. Results: All 10 beagle dogs completed the marking and exploration successfully. The average distance between the magnetic beads and the positioning titanium clip in 20 cases was 5.90±2.36 mm. The average detection time was 1.60±0.69 min, and the average magnetic induction intensity was 3.76±1.11 mT. No magnetic beads were found to fall off, 1 case had a mild mucosal injury, and 2 cases had a small amount of bleeding when releasing the positioning titanium clip. The white blood cells before and 24 hours after the operation were 7.43±0.94(×10 9 /L) versus 7.79±0.67(×10 9 /L) ( P =0.34). The C-reactive protein before and 24 hours after the operation were 5.24±0.97 µg/mL versus 5.95±1.02 µg/mL ( P =0.13). Conclusion: A magnetic detector combined with magnetic beads for gastric cancer labeling is feasible, accurate, and safe. It is expected to be further applied in the clinic. … (more)
- Is Part Of:
- Surgical laparoscopy endoscopy & percutaneous techniques. Volume 33:Issue 1(2023)
- Journal:
- Surgical laparoscopy endoscopy & percutaneous techniques
- Issue:
- Volume 33:Issue 1(2023)
- Issue Display:
- Volume 33, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2023-0033-0001-0000
- Page Start:
- 89
- Page End:
- 94
- Publication Date:
- 2023-02-19
- Subjects:
- preoperative labeling -- embryonic natural orifice transumbilical endoscopic surgery -- magnetic detector -- magnetic technique
Endoscopic surgery -- Periodicals
Laparoscopic surgery -- Periodicals
Endoscopy -- Periodicals
Laparoscopy -- Periodicals
617.550597 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00019509-000000000-00000 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00129689-000000000-00000 ↗
http://www.surgical-laparoscopy.com ↗
http://journals.lww.com/surgical-laparoscopy/pages/default.aspx ↗
http://journals.lww.com ↗
http://www.lww.com/Product/1530-4515 ↗ - DOI:
- 10.1097/SLE.0000000000001134 ↗
- Languages:
- English
- ISSNs:
- 1530-4515
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8548.234200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25699.xml