Deep learning-based automatic left atrial appendage filling defects assessment on cardiac computed tomography for clinical and subclinical atrial fibrillation patients. Issue 1 (January 2023)
- Record Type:
- Journal Article
- Title:
- Deep learning-based automatic left atrial appendage filling defects assessment on cardiac computed tomography for clinical and subclinical atrial fibrillation patients. Issue 1 (January 2023)
- Main Title:
- Deep learning-based automatic left atrial appendage filling defects assessment on cardiac computed tomography for clinical and subclinical atrial fibrillation patients
- Authors:
- Chen, Ling
Huang, Sung-Hao
Wang, Tzu-Hsiang
Lan, Tzuo-Yun
Tseng, Vincent S.
Tsao, Hsuan-Ming
Wang, Hsueh-Han
Tang, Gau-Jun - Abstract:
- Abstract: Rationale and objectives: Selecting region of interest (ROI) for left atrial appendage (LAA) filling defects assessment can be time consuming and prone to subjectivity. This study aimed to develop and validate a novel artificial intelligence (AI), deep learning (DL) based framework for automatic filling defects assessment on CT images for clinical and subclinical atrial fibrillation (AF) patients. Materials and methods: A total of 443, 053 CT images were used for DL model development and testing. Images were analyzed by the AI framework and expert cardiologists/radiologists. The LAA segmentation performance was evaluated using Dice coefficient. The agreement between manual and automatic LAA ROI selections was evaluated using intraclass correlation coefficient (ICC) analysis. Receiver operating characteristic (ROC) curve analysis was used to assess filling defects based on the computed LAA to ascending aorta Hounsfield unit (HU) ratios. Results: A total of 210 patients (Group 1: subclinical AF, n = 105; Group 2: clinical AF with stroke, n = 35; Group 3: AF for catheter ablation, n = 70) were enrolled. The LAA volume segmentation achieved 0.931–0.945 Dice scores. The LAA ROI selection demonstrated excellent agreement (ICC ≥0.895, p < 0.001) with manual selection on the test sets. The automatic framework achieved an excellent AUC score of 0.979 in filling defects assessment. The ROC-derived optimal HU ratio threshold for filling defects detection was 0.561.Abstract: Rationale and objectives: Selecting region of interest (ROI) for left atrial appendage (LAA) filling defects assessment can be time consuming and prone to subjectivity. This study aimed to develop and validate a novel artificial intelligence (AI), deep learning (DL) based framework for automatic filling defects assessment on CT images for clinical and subclinical atrial fibrillation (AF) patients. Materials and methods: A total of 443, 053 CT images were used for DL model development and testing. Images were analyzed by the AI framework and expert cardiologists/radiologists. The LAA segmentation performance was evaluated using Dice coefficient. The agreement between manual and automatic LAA ROI selections was evaluated using intraclass correlation coefficient (ICC) analysis. Receiver operating characteristic (ROC) curve analysis was used to assess filling defects based on the computed LAA to ascending aorta Hounsfield unit (HU) ratios. Results: A total of 210 patients (Group 1: subclinical AF, n = 105; Group 2: clinical AF with stroke, n = 35; Group 3: AF for catheter ablation, n = 70) were enrolled. The LAA volume segmentation achieved 0.931–0.945 Dice scores. The LAA ROI selection demonstrated excellent agreement (ICC ≥0.895, p < 0.001) with manual selection on the test sets. The automatic framework achieved an excellent AUC score of 0.979 in filling defects assessment. The ROC-derived optimal HU ratio threshold for filling defects detection was 0.561. Conclusion: The novel AI-based framework could accurately segment the LAA region and select ROIs while effectively avoiding trabeculae for filling defects assessment, achieving close-to-expert performance. This technique may help preemptively detect the potential thromboembolic risk for AF patients. Graphical abstract: Image 1 … (more)
- Is Part Of:
- Heliyon. Volume 9:Issue 1(2023)
- Journal:
- Heliyon
- Issue:
- Volume 9:Issue 1(2023)
- Issue Display:
- Volume 9, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 9
- Issue:
- 1
- Issue Sort Value:
- 2023-0009-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01
- Subjects:
- Left atrial appendage -- Atrial fibrillation -- Computed tomography -- Artificial intelligence -- Deep learning
AA Ascending aorta -- AF Atrial fibrillation -- AI Artificial intelligence -- AUC Area under the ROC curve -- CI Confidence interval -- DL Deep learning -- ECG Electrocardiogram -- HU Hounsfield unit -- ICC Intraclass correlation coefficient -- LAA Left atrial appendage -- ROC Receiver operating characteristics -- ROI Region of interest -- SD Standard deviation
Research -- Periodicals
Medical sciences -- Periodicals
Natural history -- Periodicals
Social sciences -- Periodicals
Earth sciences -- Periodicals
Physical sciences -- Periodicals
507.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/24058440/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.heliyon.2023.e12945 ↗
- Languages:
- English
- ISSNs:
- 2405-8440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25684.xml