Single measurement estimation of central blood pressure using an arterial transfer function. (February 2023)
- Record Type:
- Journal Article
- Title:
- Single measurement estimation of central blood pressure using an arterial transfer function. (February 2023)
- Main Title:
- Single measurement estimation of central blood pressure using an arterial transfer function
- Authors:
- Murphy, Liam
Chase, J. Geoffrey - Abstract:
- Highlights: Central pressure can be accurately estimated from peripheral pressure measurements alone Pulse wave analysis of peripheral pressures allowed for initial approximations of central pressure and flow contour Experimental data from porcine endotoxin experiments provided a diverse range of hemodynamic conditions for validation The method was validated against direct measurements of aortic pressure Abstract: Background: Central blood pressure (BP) better reflects the loading conditions on the major organs and is more closely correlated with future cardiovascular events. The increased invasiveness and risk of infection prevents the routine measurement of central BP. Arterial transfer functions can provide central BP estimates from clinically available peripheral measurements. However, current methods are either generalized, potentially lacking the ability to adapt to inter and intra subject variability, or individualized based on additional, clinically unavailable, pulse transit time measurements. This work proposes a novel, self-contained method for individualizing an arterial transfer function from a single peripheral pressure measurement, capable of accurately estimating central BP in a range of hemodynamic conditions. Methods: Pulse wave analysis of femoral BP waves was employed to formulate initial approximations of central BP and arterial inlet flow waveforms, to serve as objective functions for the identification of all model parameters. Root mean squared errorHighlights: Central pressure can be accurately estimated from peripheral pressure measurements alone Pulse wave analysis of peripheral pressures allowed for initial approximations of central pressure and flow contour Experimental data from porcine endotoxin experiments provided a diverse range of hemodynamic conditions for validation The method was validated against direct measurements of aortic pressure Abstract: Background: Central blood pressure (BP) better reflects the loading conditions on the major organs and is more closely correlated with future cardiovascular events. The increased invasiveness and risk of infection prevents the routine measurement of central BP. Arterial transfer functions can provide central BP estimates from clinically available peripheral measurements. However, current methods are either generalized, potentially lacking the ability to adapt to inter and intra subject variability, or individualized based on additional, clinically unavailable, pulse transit time measurements. This work proposes a novel, self-contained method for individualizing an arterial transfer function from a single peripheral pressure measurement, capable of accurately estimating central BP in a range of hemodynamic conditions. Methods: Pulse wave analysis of femoral BP waves was employed to formulate initial approximations of central BP and arterial inlet flow waveforms, to serve as objective functions for the identification of all model parameters. Root mean squared error (RMSE), and systolic and pulse pressure errors were assessed with respect to invasive aortic BP measurements in a seven (7) porcine endotoxin experiments. Systolic and pulse pressure errors were analysed using Bland-Altman analysis. Method accuracy is also compared with an idealized transfer function, derived using the measured aortic-femoral pulse transit time and minimizing the RMSE of model output pressure with respect to reference aortic pressure, a generalized transfer function model, and invasive femoral pressure measurements. Results: Mean bias and limits of agreement (95% CI) for the proposed method were 1.0(-4.6, 6.7)mmHg and -1.0(-6.6, 4.6)mmHg for systolic and pulse pressure, respectively, compared to 3.6(-0.9, 8.2)mmHg and 2.7(-1.8, 7.3)mmHg for the generalized transfer function model. Mean bias and limits of agreement for femoral pressure measurements were -6.4(-15.0, 2.3)mmHg and -9.4(-18.1, -0.8)mmHg, for systolic and pulse pressure, respectively. The pooled mean and standard deviation of the RMSE produced by the single measurement method, relative to reference aortic pressure, was 4.3(1.1)mmHg, consistent with estimates produced by the idealized transfer function, 3.9(1.2)mmHg, and improving of the generalized transfer function, 4.6(1.4)mmHg. Conclusions: The proposed single measurement method provides accurate central BP estimates from routinely available peripheral pressure measurements, and nothing else. The method allows for the individualization of transfer functions on a per patient basis to better capture changes in patient condition during the progression of disease and subsequent treatment, at no additional clinical cost. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 229(2023)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 229(2023)
- Issue Display:
- Volume 229, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 229
- Issue:
- 2023
- Issue Sort Value:
- 2023-0229-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-02
- Subjects:
- Central blood pressure -- Pulse wave analysis -- Pulse transit time -- Wave reflection -- Transfer function -- Tube-load model
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2022.107254 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25663.xml