Clinical value of cardiovascular magnetic resonance in patients with MR-conditional pacemakers. (20th November 2015)
- Record Type:
- Journal Article
- Title:
- Clinical value of cardiovascular magnetic resonance in patients with MR-conditional pacemakers. (20th November 2015)
- Main Title:
- Clinical value of cardiovascular magnetic resonance in patients with MR-conditional pacemakers
- Authors:
- Raphael, Claire E.
Vassiliou, Vassilis
Alpendurada, Francisco
Prasad, Sanjay K.
Pennell, Dudley J.
Mohiaddin, Raad H. - Abstract:
- Abstract: Aims: Magnetic resonance (MR) conditional pacemakers are increasingly implanted into patients who may need cardiovascular MR (CMR) subsequent to device implantation. We assessed the added value of CMR for diagnosis and management in this population. Methods and results: CMR and pacing data from consecutive patients with MR conditional pacemakers were retrospectively reviewed. Images were acquired at 1.5 T (Siemens Magnetom Avanto). The indication for CMR and any resulting change in management was recorded. The quality of CMR was rated by an observer blinded to clinical details, and data on pacemaker and lead parameters were collected pre- and post-CMR. Seventy-two CMR scans on 69 patients performed between 2011 and 2015 were assessed. All scans were completed successfully with no significant change in lead thresholds or pacing parameters. Steady-state free precession (SSFP) cine imaging resulted in a greater frequency of non-diagnostic imaging (22 vs. 1%, P < 0.01) compared with gradient echo sequences (GRE). Right-sided pacemakers were associated with less artefact than left-sided pacemakers. Late gadolinium enhancement imaging was performed in 59 scans with only 2% of segments rated of non-diagnostic quality. The CMR data resulted in a new diagnosis in 27 (38%) of examinations; clinical management was changed in a further 18 (25%). Conclusions: CMR in patients with MR conditional pacemakers provided diagnostic or management-changing information in the majorityAbstract: Aims: Magnetic resonance (MR) conditional pacemakers are increasingly implanted into patients who may need cardiovascular MR (CMR) subsequent to device implantation. We assessed the added value of CMR for diagnosis and management in this population. Methods and results: CMR and pacing data from consecutive patients with MR conditional pacemakers were retrospectively reviewed. Images were acquired at 1.5 T (Siemens Magnetom Avanto). The indication for CMR and any resulting change in management was recorded. The quality of CMR was rated by an observer blinded to clinical details, and data on pacemaker and lead parameters were collected pre- and post-CMR. Seventy-two CMR scans on 69 patients performed between 2011 and 2015 were assessed. All scans were completed successfully with no significant change in lead thresholds or pacing parameters. Steady-state free precession (SSFP) cine imaging resulted in a greater frequency of non-diagnostic imaging (22 vs. 1%, P < 0.01) compared with gradient echo sequences (GRE). Right-sided pacemakers were associated with less artefact than left-sided pacemakers. Late gadolinium enhancement imaging was performed in 59 scans with only 2% of segments rated of non-diagnostic quality. The CMR data resulted in a new diagnosis in 27 (38%) of examinations; clinical management was changed in a further 18 (25%). Conclusions: CMR in patients with MR conditional pacemakers provided diagnostic or management-changing information in the majority (63%) of our cohort. The use of gradient echo cine sequences can reduce rates of non-diagnostic imaging. Right-sided device implantation may be considered in patients likely to require CMR examination. … (more)
- Is Part Of:
- European heart journal. Volume 17:Number 10(2016:Oct.)
- Journal:
- European heart journal
- Issue:
- Volume 17:Number 10(2016:Oct.)
- Issue Display:
- Volume 17, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 10
- Issue Sort Value:
- 2016-0017-0010-0000
- Page Start:
- 1178
- Page End:
- 1185
- Publication Date:
- 2015-11-20
- Subjects:
- cardiovascular magnetic resonance -- CMR -- pacemaker -- conditional -- PPM
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jev305 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25676.xml