Reproducibility of functional aortic analysis using magnetic resonance imaging: the MESA. (10th September 2015)
- Record Type:
- Journal Article
- Title:
- Reproducibility of functional aortic analysis using magnetic resonance imaging: the MESA. (10th September 2015)
- Main Title:
- Reproducibility of functional aortic analysis using magnetic resonance imaging: the MESA
- Authors:
- Noda, Chikara
Ambale Venkatesh, Bharath
Ohyama, Yoshiaki
Liu, Chia-Ying
Chamera, Elzbieta
Redheuil, Alban
Teixido-Tura, Gisela
Chugh, Atul R.
Wu, Colin O.
Hundley, Gregory W.
Bluemke, David A.
Lima, Joao A.C. - Abstract:
- Abstract: Aims: To assess the test–retest, intra- and inter-reader reliability of thoracic aorta measurements by magnetic resonance imaging (MRI). Methods and results: Twenty-five participants underwent aortic MRI twice over 13 ± 7 days. All aortic variables from baseline and repeat MR were analysed using a semi-automated method by the ARTFUN software. To assess the inter-study reproducibility of aortic variables, we calculated intraclass correlation coefficient (ICC) for individual aortic measurements. Intra- and inter-observer variability was also assessed using the baseline MR data. Mean ascending aortic strain had moderate inter-study reproducibility (11.53 ± 6.44 vs. 10.55 ± 6.64, P = 0.443, ICC = 0.53, P < 0.01). Mean descending aortic strain and arch pulse wave velocity (PWV) had good inter-study reproducibility (descending aortic strain: 8.65 ± 5.30 vs. 8.35 ± 5.26, P = 0.706, ICC = 0.74, P < 0.001; PWV: 9.92 ± 4.18 vs. 9.94 ± 4.55, P = 0.968, ICC = 0.77, P < 0.001, respectively). All aortic variables had excellent intra- and inter-observer reproducibility (intra-: ICC range, 0.87–0.99, inter-: ICC range, 0.56–0.99, respectively). Conclusion: Inter-study reproducibility of all aortic variables was acceptable. Intra- and inter-observer reproducibility of all aortic variables was excellent. MRI can provide a repeatable method of measuring aortic structural and functional parameters.
- Is Part Of:
- European heart journal. Volume 17:Number 8(2016:Aug.)
- Journal:
- European heart journal
- Issue:
- Volume 17:Number 8(2016:Aug.)
- Issue Display:
- Volume 17, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 8
- Issue Sort Value:
- 2016-0017-0008-0000
- Page Start:
- 909
- Page End:
- 917
- Publication Date:
- 2015-09-10
- Subjects:
- aorta -- reproducibility -- pulse wave velocity -- strain -- MRI -- phase contrast
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jev215 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25663.xml