Absolute flow or myocardial flow reserve for the detection of significant coronary artery disease?. (9th January 2014)
- Record Type:
- Journal Article
- Title:
- Absolute flow or myocardial flow reserve for the detection of significant coronary artery disease?. (9th January 2014)
- Main Title:
- Absolute flow or myocardial flow reserve for the detection of significant coronary artery disease?
- Authors:
- Joutsiniemi, Esa
Saraste, Antti
Pietilä, Mikko
Mäki, Maija
Kajander, Sami
Ukkonen, Heikki
Airaksinen, Juhani
Knuuti, Juhani - Abstract:
- Abstract: Objectives: We compared the accuracy of quantified myocardial flow reserve and absolute stress myocardial blood flow (MBF) alone in the detection of coronary artery disease (CAD). Background: Myocardial flow reserve, i.e. ratio of stress and rest flow, has been commonly used to detect CAD with many imaging modalities. However, it is not known whether absolute stress flow alone is sufficient for detection of significant CAD. Methods: We enrolled 104 patients with moderate (30–70%) pre-test likelihood of CAD without previous myocardial infarction. MBF was measured by positron emission tomography and O-15-water at rest and during the adenosine stress in the regions of the left anterior descending, left circumflex, and right coronary artery. All the patients underwent invasive coronary angiography including the measurement of fractional flow reserve when appropriate. Results: Quantified myocardial flow reserve (optimal cut-off value 2.5) detected significant coronary stenosis with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 81, 87, 66 and 94%, respectively. When compared with flow reserve, absolute MBF at stress (optimal cut-off value of 2.4 mL/min/g) was more accurate in detecting significant coronary stenosis [area under the curve (AUC) 0.94 vs. 0.90, P = 0.02] with sensitivity, specificity, PPV, and NPV of 95% ( P = 0.03 vs. flow reserve), 90, 73, and 98%, respectively. An absolute increase of MBF from rest toAbstract: Objectives: We compared the accuracy of quantified myocardial flow reserve and absolute stress myocardial blood flow (MBF) alone in the detection of coronary artery disease (CAD). Background: Myocardial flow reserve, i.e. ratio of stress and rest flow, has been commonly used to detect CAD with many imaging modalities. However, it is not known whether absolute stress flow alone is sufficient for detection of significant CAD. Methods: We enrolled 104 patients with moderate (30–70%) pre-test likelihood of CAD without previous myocardial infarction. MBF was measured by positron emission tomography and O-15-water at rest and during the adenosine stress in the regions of the left anterior descending, left circumflex, and right coronary artery. All the patients underwent invasive coronary angiography including the measurement of fractional flow reserve when appropriate. Results: Quantified myocardial flow reserve (optimal cut-off value 2.5) detected significant coronary stenosis with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 81, 87, 66 and 94%, respectively. When compared with flow reserve, absolute MBF at stress (optimal cut-off value of 2.4 mL/min/g) was more accurate in detecting significant coronary stenosis [area under the curve (AUC) 0.94 vs. 0.90, P = 0.02] with sensitivity, specificity, PPV, and NPV of 95% ( P = 0.03 vs. flow reserve), 90, 73, and 98%, respectively. An absolute increase of MBF from rest to stress by <1.5 mL/g/min had also similar accuracy in detecting CAD (AUC: 0.95). The results were comparable in patients who did and did not receive i.v. beta-blockers prior imaging. Conclusions: Absolute stress perfusion alone was superior to perfusion reserve in the detection of haemodynamically significant CAD and allows shorter imaging protocols with smaller radiation dose. … (more)
- Is Part Of:
- European heart journal. Volume 15:Number 6(2014:Jun.)
- Journal:
- European heart journal
- Issue:
- Volume 15:Number 6(2014:Jun.)
- Issue Display:
- Volume 15, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 6
- Issue Sort Value:
- 2014-0015-0006-0000
- Page Start:
- 659
- Page End:
- 665
- Publication Date:
- 2014-01-09
- Subjects:
- Positron emission tomography -- Coronary artery disease -- Myocardial perfusion imaging -- Myocardial blood flow -- Myocardial perfusion reserve
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jet274 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25684.xml